Test terminal strip, VDE coded type A14, A detailed circuit diagram can be found under Miscellaneous Downloads, nom. voltage: 400 V AC/DC, connection method: Screw connection, number of connections: 28, number of positions: 14, cross section: 0.2 mm² - 10
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3069413 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Short-time current 150 A
- Number of positions 14
- Color gray
- Overvoltage category III
- Finger protection guaranteed
- Note regarding shock protection When plugged in
- Bending test rotation speed 10 rpm
- Result of tight fit on support Test passed
- Result of temperature-rise test Test passed
- Note 25 pos.
- Potentials 14
- Rated surge voltage 4 kV
- Insulating material group I
- Open side panel No
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of power-frequency withstand voltage test Test passed
- Setpoint 5 N
- Result of aging test Test passed
- Result of thermal test Test passed
- ASD level 6.12 (m/s2)2/Hz
- Number of shocks per direction 3
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Stripping length 12 mm
- Number of levels 1
- Test surge voltage 5 kV
- Maximum load current 30 A (with 10 mm² conductor cross section)
- Back of the hand protection guaranteed
- Power frequency withstand voltage setpoint 1.89 kV
- Bending test conductor cross section/weight 0.2 mm² / 0.2 kg
- Result of voltage-drop test Test passed
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Screw thread M4
- Connection 1 level
- Conductor cross section AWG min. 24
- Flammability rating according to UL 94 V0
- Nominal cross section 6 mm²
- Maximum power dissipation for nominal condition 1.31 W
- Result of surge voltage test Test passed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Tensile test result Test passed
- Conductor cross section short circuit testing 4 mm²
- Ageing test for screwless modular terminal block temperature cycles 192
- Acceleration 30g
- Shock test result Test passed
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Surface flammability NFPA 130 (ASTM E 162) passed
- Number of connections 28
- Insulating material PA
- Nominal voltage UN 400 V AC/DC
- Terminal block mounting 0.8 Nm ... 1 Nm
- Result of flexion and pull-out test Test passed
- Bending test turns 135
- Short circuit stability result Test passed
- Test spectrum Service life test category 2, bogie-mounted
- Test duration per axis 5 h
- Shock duration 18 ms
- Shock form Half-sine
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Length 100 mm
- Plate thickness 1 mm ... 4 mm
- Height 56.5 mm
- Tightening torque, min 1.5 Nm
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
- 2 conductors with same cross section, solid max. 2.5 mm²
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Pitch 8.2 mm
- Tightening torque max 1.8 Nm
- Conductor cross section flexible max. 10 mm²
- Conductor cross section AWG max. 8
- Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- ECLASS 5.1 27141100
- ETIM 3.0 EC000901
- UNSPSC 7.0901 39121410
- UNSPSC 20.0 39121410
- UNSPSC 21.0 39121410
- ECLASS 4.0 27141100
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 5.0 27141100
- ETIM 6.0 EC000902
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Internal cylindrical gage A5
- ECLASS 9.0 27141126
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Oscillation, broadband noise test result Test passed
- Max. tightening torque of the mounting screw: 1 Nm
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 7.0 27141126
- UNSPSC 6.01 30211811
- UNSPSC 13.2 39121410
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 10.0.1 27141126
- ECLASS 6.0 27141100
- ETIM 7.0 EC000902
- UNSPSC 11 39121410
- UNSPSC 12.01 39121410
- UNSPSC 19.0 39121410
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- 2 conductors with same cross section, solid min. 0.2 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- Min. tightening torque of the mounting screw: 0.8 Nm
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- 2 conductors with same cross section, stranded min. 0.2 mm²
- 2 conductors with same cross section, stranded max. 2.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- REACh SVHC Lead 7439-92-1
- Width 147.6 mm
- Connection in acc. with standard IEC 60947-7-1
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 6 mm²
- ECLASS 4.1 27141100
- ETIM 4.0 EC000897
- Max. AWG conductor cross section, flexible 8
- Connection method Screw connection
- Conductor cross section solid max. 10 mm²
- Min. AWG conductor cross section, flexible 24
- Mounting type Wall mounting
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 11.0 27141126
- UNSPSC 18.0 39121410
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨