3045499 Phoenix Contact Terminal Blocks
Part#:3045499
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Plug, number of positions: 10, connection method: Screw connection, cross section: 0.14 mm²- 4 mm², AWG: 26 - 12, nominal current: 24 A, nom. voltage: 500 V, width: 52 mm, color: gray
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3045499 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Potentials 1
- Rated surge voltage 6 kV
- Maximum load current 24 A (with 4 mm² conductor cross section)
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Length 20.5 mm
- Stripping length 9 mm
- Color gray
- Insulating material group I
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Connection method Screw connection
- Connection in acc. with standard CUL
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- 2 conductors with same cross section, stranded min. 0.14 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 4.1 27260700
- ECLASS 6.0 27141100
- ETIM 4.0 EC002021
- UNSPSC 11 39121402
- UNSPSC 20.0 39121402
- Number of positions 10
- Flammability rating according to UL 94 V0
- Maximum power dissipation for nominal condition 0.77 W
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Width 52 mm
- Screw thread M3
- Conductor cross section solid min. 0.14 mm²
- Conductor cross section flexible max. 4 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
- 2 conductors with same cross section, stranded max. 1.5 mm²
- Internal cylindrical gage A3
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 11.0 27141151
- ECLASS 7.0 27141151
- ETIM 6.0 EC002021
- UNSPSC 12.01 39121402
- UNSPSC 21.0 39121402
- UNSPSC 19.0 39121402
- Nominal cross section 2.5 mm²
- Degree of pollution 3
- Nominal current IN 24 A
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Height 47 mm
- Tightening torque, min 0.5 Nm
- Conductor cross section AWG min. 26
- Max. AWG conductor cross section, flexible 12
- 2 conductors with same cross section, solid min. 0.14 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 1 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.0 27260700
- ETIM 2.0 EC000897
- UNSPSC 6.01 30211802
- UNSPSC 18.0 39121402
- Insulating material PA
- Overvoltage category III
- Nominal voltage UN 500 V
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Pitch 5.2 mm
- Tightening torque max 0.6 Nm
- Conductor cross section AWG max. 12
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
- 2 conductors with same cross section, solid max. 1.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.14 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 10.0.1 27141151
- ECLASS 5.1 27260700
- ETIM 3.0 EC000897
- UNSPSC 7.0901 39121402
- Conductor cross section solid max. 4 mm²
- Min. AWG conductor cross section, flexible 26
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27260700
- ECLASS 9.0 27141151
- ETIM 7.0 EC002021
- UNSPSC 13.2 39121402
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨