About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3045091 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Result of flexion and pull-out test Test passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Acceleration 5g
- Tightening torque, min 0.5 Nm
- Shock duration 30 ms
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Potentials 1
- Width 5.2 mm
- Height NS 35/15 55 mm
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Length 47.7 mm
- Conductor cross section AWG max. 12
- 2 conductors with same cross section, solid min. 0.14 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 1.5 mm²
- Stripping length 9 mm
- Conductor cross section solid max. 4 mm²
- Internal cylindrical gage A3
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Height NS 35/7,5 47.5 mm
- Conductor cross section solid min. 0.14 mm²
- Min. AWG conductor cross section, flexible 26
- 2 conductors with same cross section, stranded min. 0.14 mm²
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Note Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- 2 conductors with same cross section, solid max. 1.5 mm²
- ECLASS 5.0 27141100
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Screw thread M3
- Connection in acc. with standard CSA
- Conductor cross section flexible max. 2.5 mm²
- 2 conductors with same cross section, stranded max. 1.5 mm²
- UNSPSC 19.0 39121410
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.14 mm²
- ETIM 3.0 EC000897
- UNSPSC 6.01 30211811
- UNSPSC 20.0 39121410
- Connection method Screw connection
- Tightening torque max 0.6 Nm
- Conductor cross section AWG min. 26
- Max. AWG conductor cross section, flexible 12
- ECLASS 6.0 27141100
- Degree of pollution 3
- Nominal current IN 24 A
- Result of surge voltage test Test passed
- Tensile test result Test passed
- Setpoint 1 N
- Result of temperature-rise test Test passed
- Test spectrum Service life test category 1, class B, body mounted
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Rated surge voltage 8 kV
- Insulating material group I
- Maximum load current 32 A (with 4 mm² conductor cross section)
- Back of the hand protection guaranteed
- Power frequency withstand voltage setpoint 2.2 kV
- Bending test turns 135
- Tight fit on carrier NS 35
- Result of thermal test Test passed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Number of connections 2
- Flammability rating according to UL 94 V0
- Insulating material PA
- Maximum power dissipation for nominal condition 0.77 W
- Finger protection guaranteed
- Open side panel Yes
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Result of tight fit on support Test passed
- Conductor cross section short circuit testing 4 mm²
- Oscillation, broadband noise test result Test passed
- ASD level 1.857 (m/s2)2/Hz
- Shock form Half-sine
- Number of levels 1
- Bending test rotation speed 10 rpm
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Result of voltage-drop test Test passed
- Short-time current 0.48 kA
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test duration per axis 5 h
- Nominal cross section 2.5 mm²
- Area of application Railway industry
- Overvoltage category III
- Nominal voltage UN 1000 V
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of power-frequency withstand voltage test Test passed
- Short circuit stability result Test passed
- End cover width 2.2 mm
- Color green
- Shock test result Test passed
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Static insulating material application in cold -60 °C
- ETIM 4.0 EC000897
- UNSPSC 13.2 39121410
- UNSPSC 12.01 39121410
- Number of shocks per direction 3
- Permissible humidity (storage/transport) 30 % ... 70 %
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 11.0 27141120
- ECLASS 7.0 27141120
- ETIM 2.0 EC000897
- UNSPSC 7.0901 39121410
- UNSPSC 18.0 39121410
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 4.0 27141100
- ECLASS 5.1 27141100
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 10.0.1 27141120
- ECLASS 4.1 27141100
- ECLASS 9.0 27141120
- ETIM 7.0 EC000897
- ETIM 6.0 EC000897
- UNSPSC 11 39121410
- UNSPSC 21.0 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$1.47
Stock:
2,969
Select Qty:
$1.47
$1.47 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨