3031364 Phoenix Contact Terminal Blocks

Phoenix Contact 3031364 Feed-through terminal block, nom. voltage: 800 V, nominal current: 32 A, connection method: Spring-cage connection, number of connections: 2, cross section: 0.08 mm² - 6 mm², AWG: 28 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3031364

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 7758

Nov 21, 2024

Feed-through terminal block, nom. voltage: 800 V, nominal current: 32 A, connection method: Spring-cage connection, number of connections: 2, cross section: 0.08 mm² - 6 mm², AWG: 28 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3031364 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • ECLASS 11.0
    27141120
  • ECLASS 4.1
    27141100
  • ECLASS 9.0
    27141120
  • ETIM 2.0
    EC000897
  • UNSPSC 13.2
    39121410
  • UNSPSC 12.01
    39121410
  • ECLASS 7.0
    27141120
  • UNSPSC 6.01
    30211811
  • UNSPSC 20.0
    39121410
  • ECLASS 6.0
    27141100
  • ETIM 7.0
    EC000897
  • ETIM 3.0
    EC000897
  • UNSPSC 19.0
    39121410
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.14 mm²
  • Nominal voltage UN
    800 V
  • Tensile test result
    Test passed
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Flammability rating according to UL 94
    V0
  • Result of flexion and pull-out test
    Test passed
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Number of levels
    1
  • Overvoltage category
    III
  • Area of application
    Railway industry
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Potentials
    1
  • Degree of pollution
    3
  • Maximum power dissipation for nominal condition
    1.02 W
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Power frequency withstand voltage setpoint
    2 kV
  • Bending test conductor cross section/weight
    0.08 mm² / 0.1 kg
  • Result of voltage-drop test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock test result
    Test passed
  • Static insulating material application in cold
    -60 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Height NS 35/7,5
    36.5 mm
  • Conductor cross section solid min.
    0.08 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • Number of connections
    2
  • Insulating material
    PA
  • Maximum load current
    40 A (with 6 mm² conductor cross section)
  • Open side panel
    Yes
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • Result of aging test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test duration per axis
    5 h
  • Shock duration
    18 ms
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Connection method
    Spring-cage connection
  • Connection in acc. with standard
    CSA
  • Conductor cross section solid max.
    6 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.14 mm²
  • ECLASS 10.0.1
    27141120
  • Color
    gray
  • Rated surge voltage
    8 kV
  • Insulating material group
    I
  • Finger protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Tight fit on carrier
    NS 35
  • Conductor cross section short circuit testing
    6 mm²
  • Result of thermal test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Acceleration
    30g
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/15
    44 mm
  • Conductor cross section AWG max.
    10
  • Max. AWG conductor cross section, flexible
    12
  • Min. AWG conductor cross section, flexible
    28
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • ECLASS 4.0
    27141100
  • ECLASS 5.0
    27141100
  • ETIM 6.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 7.0901
    39121410
  • Result of surge voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Bending test turns
    135
  • Setpoint
    1 N
  • Short-time current
    0.72 kA
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock form
    Half-sine
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Width
    6.2 mm
  • Connection
    1 level
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible min.
    0.08 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ETIM 4.0
    EC000897
  • UNSPSC 18.0
    39121410
  • UNSPSC 21.0
    39121410
  • Result of temperature-rise test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Number of shocks per direction
    3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Length
    56 mm
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section AWG min.
    28
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Internal cylindrical gage
    A4
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.1
    27141100
  • Nominal current IN
    32 A
  • Back of the hand protection
    guaranteed
  • Nominal cross section
    4 mm²

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$2.67

Stock:

7,758

Select Qty:

$2.67

$2.67 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo