Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3009118 Phoenix Contact Terminal Blocks

Phoenix Contact 3009118 High-current terminal block, nom. voltage: 1000 V, nominal current: 150 A, connection method: Screw connection, number of connections: 2, cross section: 16 mm² - 70 mm², AWG: 6 - 2/0, width: 20 mm, height: 76 mm, color: gray, mounting type: NS 35/7,5, NS
Phoenix Contact

Part#:3009118

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 174

Sep 20, 2024

High-current terminal block, nom. voltage: 1000 V, nominal current: 150 A, connection method: Screw connection, number of connections: 2, cross section: 16 mm² - 70 mm², AWG: 6 - 2/0, width: 20 mm, height: 76 mm, color: gray, mounting type: NS 35/7,5, NS

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3009118 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Height
    76 mm
  • Length
    70.5 mm
  • Tightening torque max
    8 Nm
  • Stripping length
    24 mm
  • Conductor cross section AWG max.
    2/0
  • 2 conductors with same cross section, stranded min.
    10 mm²
  • Min. AWG conductor cross section, flexible
    3
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    16 mm²
  • Height NS 32
    81 mm
  • Conductor cross section solid min.
    16 mm²
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    50 mm²
  • Conductor cross section solid max.
    70 mm²
  • Max. AWG conductor cross section, flexible
    2/0
  • 2 conductors with same cross section, solid max.
    16 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Insulating material group
    I
  • Open side panel
    No
  • Result of flexion and pull-out test
    Test passed
  • Height NS 35/15
    83.5 mm
  • Connection method
    Screw connection
  • Note
    Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
  • UNSPSC 18.0
    39121410
  • Number of connections
    2
  • Rated surge voltage
    8 kV
  • Nominal current IN
    150 A
  • Result of power-frequency withstand voltage test
    Test passed
  • Width
    20 mm
  • Screw thread
    M6
  • Connection in acc. with standard
    CSA
  • Conductor cross section flexible min.
    25 mm²
  • 2 conductors with same cross section, solid min.
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    25 mm²
  • ECLASS 4.0
    27141100
  • ETIM 6.0
    EC000897
  • ECLASS 11.0
    27141120
  • ECLASS 6.0
    27141100
  • ECLASS 9.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 13.2
    39121410
  • UNSPSC 21.0
    39121410
  • Potentials
    1
  • Insulating material
    PA
  • Degree of pollution
    3
  • Nominal voltage UN
    1000 V
  • Tightening torque, min
    6 Nm
  • Conductor cross section AWG min.
    6
  • Conductor cross section flexible max.
    70 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    50 mm²
  • 2 conductors with same cross section, stranded max.
    16 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 125°C)
  • Tight fit on carrier
    NS 32/NS 35
  • Result of tight fit on support
    Test passed
  • Result of thermal test
    Test passed
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Result of surge voltage test
    Test passed
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.1
    27141100
  • ECLASS 7.0
    27141120
  • ETIM 2.0
    EC000897
  • UNSPSC 11
    39121410
  • Color
    gray
  • Maximum power dissipation for nominal condition
    4.73 W
  • Back of the hand protection
    guaranteed
  • Bending test rotation speed
    10 rpm
  • Tensile test result
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • UNSPSC 12.01
    39121410
  • UNSPSC 20.0
    39121410
  • ETIM 4.0
    EC000897
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410
  • ECLASS 10.0.1
    27141120
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141100
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    25 mm²
  • Nominal cross section
    50 mm²
  • Number of levels
    1
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Maximum load current
    150 A (with 50 mm² conductor cross section)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Bending test turns
    135
  • Short circuit stability result
    Test passed
  • Result of temperature-rise test
    Test passed
  • Short-time current
    6 kA
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Note regarding shock protection
    Finger-safe protection is not guaranteed if bridges are positioned.
  • Bending test conductor cross section/weight
    25 mm² / 4.5 kg
  • Setpoint
    10 N
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Internal cylindrical gage
    B10
  • Finger protection
    guaranteed
  • Result of voltage-drop test
    Test passed
  • Conductor cross section short circuit testing
    50 mm²
  • Static insulating material application in cold
    -60 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    10 mm²
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$39.97

Stock:

174

Select Qty:

$39.97

$39.97 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo