3008012 Phoenix Contact Terminal Blocks

Phoenix Contact 3008012 Feed-through terminal block, nom. voltage: 1000 V, nominal current: 125 A, connection method: Screw connection, number of connections: 2, cross section: 0.75 mm² - 50 mm², AWG: 18 - 1/0, width: 15.1 mm, color: gray, mounting type: NS 35/7,5, NS 35/15, NS
Phoenix Contact

Part#:3008012

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 3542

Nov 21, 2024

Feed-through terminal block, nom. voltage: 1000 V, nominal current: 125 A, connection method: Screw connection, number of connections: 2, cross section: 0.75 mm² - 50 mm², AWG: 18 - 1/0, width: 15.1 mm, color: gray, mounting type: NS 35/7,5, NS 35/15, NS

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3008012 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    35 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    6 mm²
  • ECLASS 9.0
    27141120
  • UNSPSC 7.0901
    39121410
  • ECLASS 4.1
    27141100
  • ECLASS 10.0.1
    27141120
  • ECLASS 5.0
    27141100
  • UNSPSC 6.01
    30211811
  • UNSPSC 20.0
    39121410
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141100
  • ETIM 2.0
    EC000897
  • ECLASS 6.0
    27141100
  • ETIM 4.0
    EC000897
  • UNSPSC 18.0
    39121410
  • ECLASS 11.0
    27141120
  • ECLASS 7.0
    27141120
  • ETIM 6.0
    EC000897
  • Insulating material
    PA
  • Number of connections
    2
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Nominal current IN
    125 A
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Bending test turns
    135
  • Setpoint
    10 N
  • Short circuit stability result
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Length
    50 mm
  • Connection method
    Screw connection
  • Connection in acc. with standard
    CSA
  • Conductor cross section AWG max.
    1/0
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Color
    gray
  • Degree of pollution
    3
  • Finger protection
    guaranteed
  • Tensile test result
    Test passed
  • Result of voltage-drop test
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Height NS 35/15
    69.5 mm
  • UNSPSC 11
    39121410
  • UNSPSC 19.0
    39121410
  • Number of levels
    1
  • Potentials
    1
  • Rated surge voltage
    8 kV
  • Maximum load current
    150 A (with 50 mm² conductor cross section)
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Tight fit on carrier
    NS 32/NS 35
  • ETIM 7.0
    EC000897
  • UNSPSC 21.0
    39121410
  • Nominal cross section
    35 mm²
  • Maximum power dissipation for nominal condition
    4.06 W
  • Nominal voltage UN
    1000 V
  • Back of the hand protection
    guaranteed
  • Bending test conductor cross section/weight
    0.75 mm² / 0.4 kg
  • Result of temperature-rise test
    Test passed
  • Result of thermal test
    Test passed
  • UNSPSC 13.2
    39121410
  • Result of flexion and pull-out test
    Test passed
  • Result of tight fit on support
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Conductor cross section short circuit testing
    50 mm²
  • Insulating material group
    I
  • Open side panel
    No
  • Result of surge voltage test
    Test passed
  • 2 conductors with same cross section, solid min.
    0.75 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.75 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC000897
  • UNSPSC 12.01
    39121410
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Stripping length
    16 mm
  • Conductor cross section solid min.
    0.75 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.75 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    35 mm²
  • 2 conductors with same cross section, stranded min.
    0.75 mm²
  • Internal cylindrical gage
    B9
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Tightening torque max
    3.7 Nm
  • Conductor cross section solid max.
    50 mm²
  • Height NS 32
    67 mm
  • Conductor cross section flexible max.
    35 mm²
  • 2 conductors with same cross section, solid max.
    16 mm²
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Tightening torque, min
    3.2 Nm
  • Conductor cross section flexible min.
    0.75 mm²
  • Conductor cross section AWG min.
    18
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.75 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    10 mm²
  • Min. AWG conductor cross section, flexible
    18
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Height NS 35/7,5
    62 mm
  • Width
    15.1 mm
  • Screw thread
    M6
  • 2 conductors with same cross section, stranded max.
    10 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Max. AWG conductor cross section, flexible
    2
  • Short-time current
    6 kA
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.75 mm²

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$25.05

Stock:

3,542

Select Qty:

$25.05

$25.05 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo