2910128 Phoenix Contact DC/DC Converters

Phoenix Contact 2910128 Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 48 V DC , output: 48 V DC / 5 A
Phoenix Contact

Part#:2910128

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 48 V DC , output: 48 V DC / 5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2910128 Phoenix Contact price in the box on the right side or send a quick quote.

2910128 Product Details

  • Comments
    Criterion A
  • Electrostatic discharge
    EN 61000-4-2
  • Electric strength, max.
    35 V DC (60 s)
  • Inrush current limitation typical
    2.3 A
  • Input fuse
    20 A (slow-blow, internal)
  • Type test (IEC/EN 60950-1) D
    0.5 kV DC
  • Production test D
    0.5 kV DC
  • Mains buffering
    typ. 17 ms (48 V DC)
  • Inrush current integral (I2t)
    < 0.1 A2s
  • Type test (IEC/EN 60950-1) B
    4 kV DC
  • Production test C
    0.5 kV DC
  • Conductor cross section solid
    0.2 mm² ... 1 mm²
  • Flexible conductor cross section flexible (ferrule, w/o plastic sleeve)
    0.2 mm² ... 1.5 mm²
  • Nominal output voltage (UN)
    48 V DC
  • Dynamic Boost (IDyn.Boost)
    10 A (5 s)
  • System deviation, static
    < 3 % (change in load, static 10 % ... 90 %)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Types of signaling
    LED
  • Analog
    4 mA ... 20 mA ±5 % (Load ≤400 Ω)
  • Output current
    5 A
  • Auxiliary converter stage
    190 kHz ... 220 kHz (Auxiliary converter stage)
  • Hood version
    Stainless steel X6Cr17
  • Height with alternative assembly
    130 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • Identification
    CB scheme (IEC 61010-1, IEC 61010-2-201)
  • Noise emission
    EN 55016
  • Discharge in air
    15 kV (Test Level 4)
  • Power frequency magnetic field
    EN 61000-4-8
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 2
    150 Hz 1.5 kHz (Test Level 3)
  • Alternating component of DC voltage
    EN 61000-4-17
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 9.0
    27210901
  • Switch-on time
    < 1 s
  • Static Boost (IStat.Boost)
    6.25 A
  • System deviation, input voltage change
    < 0.3 % (change in input voltage ±10 %)
  • Connection in series
    yes
  • UIn
    > 0.8 x UInNom (LED off)
  • Digital
    0 V DC
  • Function
    Signal ground
  • Voltage
    1 kV
  • Degree of protection
    IP20
  • Depth
    125 mm
  • Efficiency
    typ. 95.2 % (48 V DC)
  • Power dissipation SLEEP MODE
    < 2 W
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Designation
    SIQ
  • DNV GL conducted interference
    Class B
  • Electromagnetic HF field
    EN 61000-4-3
  • Fast transients (burst)
    EN 61000-4-4
  • Signal
    2 kV (Test Level 3 - asymmetrical)
  • Test level 1
    15 Hz 150 Hz (Test Level 3)
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Attenuated oscillating wave
    EN 61000-4-18
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Typical current consumption
    6.8 A (48 V DC)
  • Insulation voltage input/output
    4 kV DC (type test)
  • Production test A
    2 kV DC
  • Stripping length
    8 mm
  • Flexible conductor cross section (ferrule with plastic sleeve)
    0.2 mm² ... 0.75 mm²
  • Conductor cross section AWG
    24 ... 16
  • Magnetic circuit breaker tripping
    A1 ... A6 / B2 / C1 ... C2 / Z1 ... Z6
  • Short-circuit-proof
    yes
  • Protection against overvoltage at the output (OVP)
    ≤ 60 V DC
  • Connection labeling
    3.4 +
  • Maximum contact load
    24 V DC
  • MTBF (IEC 61709, SN 29500)
    > 1476000 h (25 °C)
  • Main converter stage
    67 kHz ... 135 kHz (Main converter stage)
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Weight
    0.8 kg
  • Ambient temperature (start-up type tested)
    -40 °C
  • Degree of pollution
    2
  • Overvoltage category EN 61010-1
    II
  • Standards/regulations
    EN 61000-4-29
  • Conducted noise emission
    EN 55016
  • Additional text
    Test Level 2
  • Test field strength
    100 A/m
  • Output
    1 kV (Test Level 3 - symmetrical)
  • I/O/S
    asymmetrical
  • Voltage dips
    EN 61000-4-29
  • Test level 3
    1.5 kHz 15 kHz (Test Level 3)
  • Test level 4
    15 kHz 150 kHz (Test Level 3)
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • ECLASS 11.0
    27210901
  • Input voltage range
    29 V DC ... 57.6 V DC
  • Typical response time
    300 ms (from SLEEP MODE)
  • Type test (IEC/EN 60950-1) A
    2 kV DC
  • Type test (IEC/EN 60950-1) C
    0.5 kV DC
  • Production test B
    2 kV DC
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Nominal output current (IN)
    5 A
  • Selective Fuse Breaking (ISFB)
    30 A (15 ms)
  • No-load proof
    yes
  • Feedback voltage resistance
    ≤ 60 V DC
  • POut
    > 100 % (LED lights up yellow, output power > 240 W)
  • Signal option
    Output current
  • Switch contact
    floating
  • Time
    428200 h
  • Side element version
    Aluminum
  • Width
    50 mm
  • Width with alternative assembly
    122 mm
  • Maximum power dissipation in no-load condition
    < 3 W
  • Vibration (operation)
    5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
  • Climatic class
    3K3 (EN 60721)
  • Standard designation
    Mains variation/undervoltage
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • DNV GL noise radiation
    Class B
  • Frequency range
    50 Hz ... 60 Hz
  • Surge voltage load (surge)
    EN 61000-4-5
  • Frequency
    0 Hz
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Test level 5
    16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • Input, output (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • ECLASS 10.0.1
    27210901
  • Connection method
    Push-in connection
  • Setting range of the output voltage (USet)
    48 V DC ... 56 V DC (> 48 V constant capacity)
  • System deviation, dynamic
    < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
  • Residual ripple
    < 50 mVPP
  • Rise time
    < 1 s (UOUT (10 % ... 90 %))
  • UOut
    > 0.9 x USet (LED lights up green)
  • Default
    Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
  • Reference potential
    to OUT1, OUT2, REM
  • Temperature
    30 °C
  • Protection class
    Special with SELV input and output
  • Height
    130 mm
  • Depth with alternative assembly
    53 mm
  • Power loss nominal load max.
    < 13 W
  • Maximum altitude
    ≤ 5000 m (> 2000 m, observe derating)
  • Overvoltage category EN 62477-1
    III
  • EMC requirements, power plant
    IEC 61850-3
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Contact discharge
    8 kV (Test Level 4)
  • Input
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Voltage dip
    0 %
  • Test level 6
    0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
  • Input, output (test level 3)
    10 MHz (Test Level 2 - asymmetrical)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2910128

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo