2910123 Phoenix Contact DC/DC Converters

Phoenix Contact 2910123 Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 24 V DC , output: 48 V DC / 5 A
Phoenix Contact

Part#:2910123

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 24 V DC , output: 48 V DC / 5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2910123 Phoenix Contact price in the box on the right side or send a quick quote.

2910123 Product Details

  • Mains buffering
    typ. 16 ms (24 V DC)
  • Insulation voltage input/output
    4 kV DC (type test)
  • Type test (IEC/EN 60950-1) D
    0.5 kV DC
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Setting range of the output voltage (USet)
    48 V DC ... 56 V DC (> 48 V constant capacity)
  • Magnetic circuit breaker tripping
    A1...A6 / B2 / C1...C2 / Z1...Z6
  • No-load proof
    yes
  • Protection against overvoltage at the output (OVP)
    ≤ 60 V DC
  • Digital
    0 V DC
  • Analog
    4 mA ... 20 mA ±5 % (Load ≤400 Ω)
  • Function
    Signal ground
  • Time
    352500 h
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Depth
    125 mm
  • Efficiency
    typ. 94 % (24 V DC)
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • EMC requirements, power plant
    IEC 61850-3
  • Identification
    CB scheme (IEC 61010-1, IEC 61010-2-201)
  • Noise emission
    EN 55016
  • Discharge in air
    15 kV (Test Level 4)
  • Comments
    Criterion A
  • Fast transients (burst)
    EN 61000-4-4
  • Power frequency magnetic field
    EN 61000-4-8
  • Voltage dip
    0 %
  • Switch-on time
    < 1 s
  • Inrush current limitation typical
    1 A (after 1 ms)
  • Production test A
    2 kV DC
  • Conductor cross section solid
    0.2 mm² ... 1 mm²
  • Nominal output voltage (UN)
    48 V DC
  • Selective Fuse Breaking (ISFB)
    30 A (15 ms)
  • Short-circuit-proof
    yes
  • Connection in series
    yes
  • Rise time
    < 1 s (UOUT (10 % ... 90 %))
  • UOut
    > 0.9 x USet (LED lights up green)
  • Signal option
    Output current
  • MTBF (IEC 61709, SN 29500)
    > 1369000 h (25 °C)
  • Degree of protection
    IP20
  • Height
    130 mm
  • Weight
    0.8 kg
  • Power loss nominal load max.
    < 16 W
  • Maximum altitude
    ≤ 5000 m (> 2000 m, observe derating)
  • Climatic class
    3K3 (EN 60721)
  • Overvoltage category EN 62477-1
    III
  • Conducted noise emission
    EN 55016
  • Additional text
    Test Level 2
  • Contact discharge
    8 kV (Test Level 4)
  • Test field strength
    100 A/m
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 4
    15 kHz 150 kHz (Test Level 3)
  • Attenuated oscillating wave
    EN 61000-4-18
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • ECLASS 11.0
    27210901
  • Electric strength, max.
    60 V DC (60 s)
  • Inrush current integral (I2t)
    < 0.01 A2s
  • Type test (IEC/EN 60950-1) A
    2 kV DC
  • Production test B
    2 kV DC
  • Stripping length
    8 mm
  • Conductor cross section AWG
    24 ... 16
  • Dynamic Boost (IDyn.Boost)
    10 A (5 s)
  • System deviation, input voltage change
    < 0.3 % (change in input voltage ±10 %)
  • Feedback voltage resistance
    ≤ 60 V DC
  • Connection labeling
    3.4 +
  • Switch contact
    floating
  • Reference potential
    to OUT1, OUT2, REM
  • Auxiliary converter stage
    190 kHz ... 220 kHz (Auxiliary converter stage)
  • Hood version
    Stainless steel X6Cr17
  • Height with alternative assembly
    130 mm
  • Power dissipation SLEEP MODE
    < 2 W
  • Vibration (operation)
    5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
  • Overvoltage category EN 61010-1
    II
  • Designation
    SIQ
  • DNV GL conducted interference
    Class B
  • DNV GL noise radiation
    Class B
  • Electromagnetic HF field
    EN 61000-4-3
  • Surge voltage load (surge)
    EN 61000-4-5
  • I/O/S
    asymmetrical
  • Voltage dips
    EN 61000-4-29
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Test level 5
    16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • Input voltage range
    18 V DC ... 32 V DC
  • Typical response time
    300 ms (from SLEEP MODE)
  • Type test (IEC/EN 60950-1) C
    0.5 kV DC
  • Production test C
    0.5 kV DC
  • Connection method
    Push-in connection
  • Flexible conductor cross section flexible (ferrule, w/o plastic sleeve)
    0.2 mm² ... 1.5 mm²
  • Static Boost (IStat.Boost)
    6.25 A
  • System deviation, static
    < 3 % (change in load, static 10 % ... 90 %)
  • Residual ripple
    < 50 mVPP
  • POut
    > 100 % (LED lights up yellow, output power > 240 W)
  • Maximum contact load
    24 V DC
  • Temperature
    30 °C
  • Main converter stage
    67 kHz ... 135 kHz (Main converter stage)
  • Side element version
    Aluminum
  • Depth with alternative assembly
    53 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standards/regulations
    EN 61000-4-29
  • Test level 2
    150 Hz 1.5 kHz (Test Level 3)
  • Input, output (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • Input, output (test level 3)
    10 MHz (Test Level 2 - asymmetrical)
  • Typical current consumption
    13.8 A (24 V DC)
  • Input fuse
    30 A (slow-blow, internal)
  • Type test (IEC/EN 60950-1) B
    4 kV DC
  • Production test D
    0.5 kV DC
  • Flexible conductor cross section (ferrule with plastic sleeve)
    0.2 mm² ... 0.75 mm²
  • Nominal output current (IN)
    5 A
  • System deviation, dynamic
    < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Types of signaling
    LED
  • UIn
    > 0.8 x UInNom (LED off)
  • Default
    Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
  • Output current
    5 A
  • Voltage
    1 kV
  • Protection class
    Special with SELV input and output
  • Width
    50 mm
  • Width with alternative assembly
    122 mm
  • Maximum power dissipation in no-load condition
    < 4 W
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Standard designation
    Mains variation/undervoltage
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Electrostatic discharge
    EN 61000-4-2
  • Frequency range
    50 Hz ... 60 Hz
  • Signal
    2 kV (Test Level 3 - asymmetrical)
  • Input
    1 kV (Test Level 3 - symmetrical)
  • Frequency
    0 Hz
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Test level 3
    1.5 kHz 15 kHz (Test Level 3)
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 9.0
    27210901
  • Test level 1
    15 Hz 150 Hz (Test Level 3)
  • Test level 6
    0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
  • Alternating component of DC voltage
    EN 61000-4-17
  • ECLASS 10.0.1
    27210901

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2910123

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo