2910123 Phoenix Contact DC/DC Converters
Part#:2910123
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 24 V DC , output: 48 V DC / 5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2910123 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight0.8 kg
- Mains buffering typ. 16 ms (24 V DC)
- Insulation voltage input/output 4 kV DC (type test)
- Type test (IEC/EN 60950-1) D 0.5 kV DC
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Setting range of the output voltage (USet) 48 V DC ... 56 V DC (> 48 V constant capacity)
- Magnetic circuit breaker tripping A1...A6 / B2 / C1...C2 / Z1...Z6
- No-load proof yes
- Protection against overvoltage at the output (OVP) ≤ 60 V DC
- Digital 0 V DC
- Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
- Function Signal ground
- Time 352500 h
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Depth 125 mm
- Efficiency typ. 94 % (24 V DC)
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- EMC requirements, power plant IEC 61850-3
- Identification CB scheme (IEC 61010-1, IEC 61010-2-201)
- Noise emission EN 55016
- Discharge in air 15 kV (Test Level 4)
- Comments Criterion A
- Fast transients (burst) EN 61000-4-4
- Power frequency magnetic field EN 61000-4-8
- Voltage dip 0 %
- Switch-on time < 1 s
- Inrush current limitation typical 1 A (after 1 ms)
- Production test A 2 kV DC
- Conductor cross section solid 0.2 mm² ... 1 mm²
- Nominal output voltage (UN) 48 V DC
- Selective Fuse Breaking (ISFB) 30 A (15 ms)
- Short-circuit-proof yes
- Connection in series yes
- Rise time < 1 s (UOUT (10 % ... 90 %))
- UOut > 0.9 x USet (LED lights up green)
- Signal option Output current
- MTBF (IEC 61709, SN 29500) > 1369000 h (25 °C)
- Degree of protection IP20
- Height 130 mm
- Power loss nominal load max. < 16 W
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- Climatic class 3K3 (EN 60721)
- Overvoltage category EN 62477-1 III
- Conducted noise emission EN 55016
- Additional text Test Level 2
- Contact discharge 8 kV (Test Level 4)
- Test field strength 100 A/m
- Output 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- Pulse-shape magnetic field EN 61000-4-9
- Test level 4 15 kHz 150 kHz (Test Level 3)
- Attenuated oscillating wave EN 61000-4-18
- Signals (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- ECLASS 11.0 27210901
- Electric strength, max. 60 V DC (60 s)
- Inrush current integral (I2t) < 0.01 A2s
- Type test (IEC/EN 60950-1) A 2 kV DC
- Production test B 2 kV DC
- Stripping length 8 mm
- Conductor cross section AWG 24 ... 16
- Dynamic Boost (IDyn.Boost) 10 A (5 s)
- System deviation, input voltage change < 0.3 % (change in input voltage ±10 %)
- Feedback voltage resistance ≤ 60 V DC
- Connection labeling 3.4 +
- Switch contact floating
- Reference potential to OUT1, OUT2, REM
- Auxiliary converter stage 190 kHz ... 220 kHz (Auxiliary converter stage)
- Hood version Stainless steel X6Cr17
- Height with alternative assembly 130 mm
- Power dissipation SLEEP MODE < 2 W
- Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
- Overvoltage category EN 61010-1 II
- Designation SIQ
- DNV GL conducted interference Class B
- DNV GL noise radiation Class B
- Electromagnetic HF field EN 61000-4-3
- Surge voltage load (surge) EN 61000-4-5
- I/O/S asymmetrical
- Voltage dips EN 61000-4-29
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- Input voltage range 18 V DC ... 32 V DC
- Typical response time 300 ms (from SLEEP MODE)
- Type test (IEC/EN 60950-1) C 0.5 kV DC
- Production test C 0.5 kV DC
- Connection method Push-in connection
- Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.2 mm² ... 1.5 mm²
- Static Boost (IStat.Boost) 6.25 A
- System deviation, static < 3 % (change in load, static 10 % ... 90 %)
- Residual ripple < 50 mVPP
- POut > 100 % (LED lights up yellow, output power > 240 W)
- Maximum contact load 24 V DC
- Temperature 30 °C
- Main converter stage 67 kHz ... 135 kHz (Main converter stage)
- Side element version Aluminum
- Depth with alternative assembly 53 mm
- Ambient temperature (start-up type tested) -40 °C
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- EMC requirements for noise immunity EN 61000-6-1
- Standards/regulations EN 61000-4-29
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Input, output (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- Input, output (test level 3) 10 MHz (Test Level 2 - asymmetrical)
- Typical current consumption 13.8 A (24 V DC)
- Input fuse 30 A (slow-blow, internal)
- Type test (IEC/EN 60950-1) B 4 kV DC
- Production test D 0.5 kV DC
- Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 0.75 mm²
- Nominal output current (IN) 5 A
- System deviation, dynamic < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- Connection in parallel Yes, for redundancy and increased capacity
- Types of signaling LED
- UIn > 0.8 x UInNom (LED off)
- Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
- Output current 5 A
- Voltage 1 kV
- Protection class Special with SELV input and output
- Width 50 mm
- Width with alternative assembly 122 mm
- Maximum power dissipation in no-load condition < 4 W
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Standard designation Mains variation/undervoltage
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electrostatic discharge EN 61000-4-2
- Frequency range 50 Hz ... 60 Hz
- Signal 2 kV (Test Level 3 - asymmetrical)
- Input 1 kV (Test Level 3 - symmetrical)
- Frequency 0 Hz
- Damped oscillating magnetic field EN 61000-4-10
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 9.0 27210901
- Test level 1 15 Hz 150 Hz (Test Level 3)
- Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
- Alternating component of DC voltage EN 61000-4-17
- ECLASS 10.0.1 27210901
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨