2910121 Phoenix Contact DC/DC Converters
Part#:2910121
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 24 V DC , output: 24 V DC / 20 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2910121 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight1.2 kg
- Typical current consumption 27 A (24 V DC)
- Insulation voltage input/output 4 kV DC (type test)
- Type test (IEC/EN 60950-1) A 2 kV DC
- Production test A 2 kV DC
- Connection method Push-in connection
- Stripping length 8 mm
- Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
- Nominal output current (IN) 20 A
- Short-circuit-proof yes
- Connection in parallel Yes, for redundancy and increased capacity
- Input voltage range 18 V DC ... 32 V DC
- Typical response time 300 ms (from SLEEP MODE)
- Type test (IEC/EN 60950-1) B 4 kV DC
- Production test C 0.5 kV DC
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Conductor cross section AWG 24 ... 16
- Static Boost (IStat.Boost) 25 A
- Magnetic circuit breaker tripping A1...A16 / B2...B13 / C1...C6 / Z1...Z16
- No-load proof yes
- Connection in series yes
- POut > 100 % (LED lights up yellow, output power > 480 W)
- Digital 0 V DC
- Switch contact floating
- Output current 20 A
- Voltage 1 kV
- Auxiliary converter stage 190 kHz ... 220 kHz (Auxiliary converter stage)
- Height 130 mm
- Height with alternative assembly 130 mm
- Depth with alternative assembly 73 mm
- Power loss nominal load max. < 26.6 W
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- Overvoltage category EN 61010-1 II
- Standards/regulations EN 61000-4-29
- Identification CB scheme (IEC 61010-1, IEC 61010-2-201)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Conducted noise emission EN 55016
- DNV GL noise radiation Class B
- Test field strength 100 A/m
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- Power frequency magnetic field EN 61000-4-8
- Test level 1 15 Hz 150 Hz (Test Level 3)
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Electric strength, max. 35 V DC (60 s)
- Switch-on time < 1 s
- Type test (IEC/EN 60950-1) C 0.5 kV DC
- Production test D 0.5 kV DC
- Conductor cross section solid 0.2 mm² ... 1 mm²
- Nominal output voltage (UN) 24 V DC
- Dynamic Boost (IDyn.Boost) 30 A (5 s)
- Selective Fuse Breaking (ISFB) 120 A (15 ms)
- System deviation, static < 3 % (change in load, static 10 % ... 90 %)
- Residual ripple < 50 mVPP
- Types of signaling LED
- Connection labeling 3.4 +
- Signal option Output current
- Reference potential to OUT1, OUT2, REM
- MTBF (IEC 61709, SN 29500) > 1034000 h (25 °C)
- Protection class Special with SELV input and output
- Side element version Aluminum
- Depth 125 mm
- Maximum power dissipation in no-load condition < 4 W
- Ambient temperature (start-up type tested) -40 °C
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Climatic class 3K3 (EN 60721)
- EMC requirements for noise immunity EN 61000-6-1
- Designation SIQ
- Additional text Test Level 2
- Electromagnetic HF field EN 61000-4-3
- Output 1 kV (Test Level 3 - symmetrical)
- Signal 2 kV (Test Level 3 - asymmetrical)
- Voltage dip 0 %
- Pulse-shape magnetic field EN 61000-4-9
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Alternating component of DC voltage EN 61000-4-17
- Input, output (test level 3) 10 MHz (Test Level 2 - asymmetrical)
- ECLASS 9.0 27210901
- Mains buffering typ. 16 ms (24 V DC)
- Inrush current limitation typical 2.7 A (after 1 ms)
- Inrush current integral (I2t) < 0.2 A2s
- Type test (IEC/EN 60950-1) D 0.5 kV DC
- Production test B 2 kV DC
- Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 0.75 mm²
- Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.2 mm² ... 1.5 mm²
- System deviation, dynamic < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- System deviation, input voltage change < 0.4 % (change in input voltage ±10 %)
- Feedback voltage resistance ≤ 35 V DC
- Rise time < 1 s (UOUT (10 % ... 90 %))
- UOut > 0.9 x USet (LED lights up green)
- Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
- Maximum contact load 24 V DC
- Time 278680 h
- Degree of protection IP20
- Hood version Stainless steel X6Cr17
- Width 70 mm
- Efficiency typ. 94.7 % (24 V DC)
- Power dissipation SLEEP MODE < 2 W
- Degree of pollution 2
- Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min, resonance frequency 2.3g, 90 min
- EMC requirements, power plant IEC 61850-3
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- DNV GL conducted interference Class B
- Electrostatic discharge EN 61000-4-2
- Discharge in air 15 kV (Test Level 4)
- Comments Criterion A
- I/O/S asymmetrical
- Frequency 0 Hz
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 11.0 27210901
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- UIn > 0.8 x UInNom (LED off)
- Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
- Function Signal ground
- Temperature 30 °C
- ECLASS 10.0.1 27210901
- Main converter stage 67 kHz ... 135 kHz (Main converter stage)
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Width with alternative assembly 122 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- Overvoltage category EN 62477-1 III
- Standard designation Mains variation/undervoltage
- Noise emission EN 55016
- Contact discharge 8 kV (Test Level 4)
- Frequency range 50 Hz ... 60 Hz
- Input 1 kV (Test Level 3 - symmetrical)
- Surge voltage load (surge) EN 61000-4-5
- Voltage dips EN 61000-4-29
- Damped oscillating magnetic field EN 61000-4-10
- Test level 4 15 kHz 150 kHz (Test Level 3)
- Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Attenuated oscillating wave EN 61000-4-18
- Input, output (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨