2909887 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2909887 Universally configurable threshold value switch with changeover contact relay output and plug-in connection technology for switching analog limit values. Configurable via DIP switch or software. Push-in connection technology, order configuration.
Phoenix Contact

Part#:2909887

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Universally configurable threshold value switch with changeover contact relay output and plug-in connection technology for switching analog limit values. Configurable via DIP switch or software. Push-in connection technology, order configuration.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2909887 Phoenix Contact price in the box on the right side or send a quick quote.

2909887 Product Details

  • Height
    109.81 mm
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Degree of protection
    IP20 (not assessed by UL)
  • Current input signal
    0 mA ... 20 mA (via DIP switch)
  • Input resistance of voltage input
    > 120 kΩ
  • Setting range of the response delay
    0 s ... 10 s (can be set freely via software)
  • Typical current consumption
    40 mA (12 V DC)
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Maximum temperature coefficient
    0.01 %/K
  • Degree of pollution
    2
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Mounting position
    any
  • DNV GL-Humidity
    B
  • DNV GL-EMC
    A
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 4.0
    27210100
  • ECLASS 9.0
    27210122
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Max. input current
    24 mA
  • Output name
    Relay output
  • Min. switching current
    100 mA (12 V DC)
  • Max. switching current
    6 A AC (250 V AC)
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Connection method
    Push-in connection
  • Maximum transmission error
    0.1 % (of final value)
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • Color
    gray
  • Conformance
    CE-compliant
  • DNV GL-Temperature
    B
  • Temperature
    B
  • EMC
    A
  • ECLASS 4.1
    27210100
  • ETIM 6.0
    EC002654
  • Width
    6.2 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • max. input voltage
    12 V
  • Maximum switching voltage
    250 V AC
  • Mechanical service life
    2x 107 cycles
  • Stripping length
    10 mm
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm² (with ferrule)
  • Switching point accuracy
    < 0.1 %
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Housing material
    PBT
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • DNV GL-Vibration
    A
  • Identification
    UL 508 Listed
  • Vibration
    A
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27210100
  • ETIM 4.0
    EC002654
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Depth
    119.2 mm
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Voltage input signal
    0 V ... 10 V (via DIP switch)
  • Input resistance current input
    approx. 50 Ω
  • Contact material
    AgSnO2, hard gold-plated
  • Nominal supply voltage
    24 V DC
  • No. of channels
    1
  • Status display
    Yellow LED (switching output)
  • Rated insulation voltage
    300 V (effective)
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Designation
    Shipbuilding approval
  • Certificate
    DNV GL TAA000021E
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 11.0
    27210122
  • ECLASS 5.0
    27210100
  • ETIM 7.0
    EC002654
  • Configurable/programmable
    Yes
  • Contact type
    1 changeover contact
  • Limiting continuous current
    6 A AC
  • Internal hysteresis
    can be set freely via software
  • Power consumption
    ≤ 0.5 W
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • Overvoltage category
    II
  • Noise emission
    EN 61000-6-4
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • UL, USA/Canada
    UL 508 Listed
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Humidity
    B
  • ECLASS 10.0.1
    27210122
  • ECLASS 5.1
    27210100
  • ECLASS 7.0
    27210122

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2909887

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo