2909886 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2909886
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Universally configurable threshold value switch with changeover contact relay output and plug-in connection technology for switching analog limit values. Configurable via DIP switch or software. Screw connection technology, order configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2909886 Phoenix Contact price in the box on the right side or send a quick quote.
2909886 Product Details
- Height 109.81 mm
- Degree of protection IP20 (not assessed by UL)
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Configurable/programmable Yes
- Input resistance of voltage input > 120 kΩ
- Output name Relay output
- Maximum switching voltage 250 V AC
- Mechanical service life 2x 107 cycles
- Max. switching current 6 A AC (250 V AC)
- Power consumption ≤ 0.5 W
- Stripping length 10 mm
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- No. of channels 1
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- Rated insulation voltage 300 V (effective)
- Electromagnetic compatibility Conformance with EMC directive
- Color gray
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- DNV GL-Temperature B
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Certificate DNV GL TAA000021E
- Temperature B
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 10.0.1 27210122
- ECLASS 5.0 27210100
- ECLASS 6.0 27210100
- ETIM 6.0 EC002654
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -40 °C ... 70 °C
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- max. input voltage 12 V
- Input resistance current input approx. 50 Ω
- Contact type 1 changeover contact
- Limiting continuous current 6 A AC
- Internal hysteresis can be set freely via software
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Connection method Screw connection
- Conductor cross section solid 0.2 mm² ... 1.5 mm² (with ferrule)
- Torque 0.5 Nm ... 0.6 Nm
- Maximum transmission error 0.1 % (of final value)
- Status display Yellow LED (switching output)
- Degree of pollution 2
- Noise emission EN 61000-6-4
- Mounting position any
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- UL, USA/Canada UL 508 Listed
- DNV GL-EMC A
- Designation Shipbuilding approval
- Humidity B
- Vibration A
- EMC A
- ECLASS 11.0 27210122
- ECLASS 4.1 27210100
- ECLASS 7.0 27210122
- ETIM 4.0 EC002654
- Width 6.2 mm
- Depth 119.2 mm
- Voltage input signal 0 V ... 10 V (via DIP switch)
- Current input signal 0 mA ... 20 mA (via DIP switch)
- Max. input current 24 mA
- Contact material AgSnO2, hard gold-plated
- Min. switching current 100 mA (12 V DC)
- Setting range of the response delay 0 s ... 10 s (can be set freely via software)
- Nominal supply voltage 24 V DC
- Typical current consumption 40 mA (12 V DC)
- Screw thread M3
- Conductor cross section AWG 24 ... 12 (flexible)
- Switching point accuracy < 0.1 %
- Maximum temperature coefficient 0.01 %/K
- Overvoltage category II
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- Housing material PBT
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- Conformance CE-compliant
- DNV GL-Humidity B
- DNV GL-Vibration A
- Identification UL 508 Listed
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27210100
- ECLASS 5.1 27210100
- ECLASS 9.0 27210122
- ETIM 7.0 EC002654
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2909886
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨