2909568 Phoenix Contact Electrical Safety Devices

Phoenix Contact 2909568 Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
Phoenix Contact

Part#:2909568

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2909568 Phoenix Contact price in the box on the right side or send a quick quote.

2909568 Product Details

  • Height
    107.5 mm
  • Degree of protection
    IP20
  • Rated actuating voltage UC
    24 V DC
  • Rated actuating current IC
    7 mA
  • Rated operating voltage Ue
    500 V AC
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10 (≤ 3 A)
  • Switching capacity according to IEC 60947-5-1
    2 A (24 V, DC13)
  • Mounting type
    DIN rail mounting
  • Maximum power dissipation
    7 W
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Rated insulation voltage
    550 V
  • Designation
    Category (ISO 13849)
  • Additional text
    Safe shutdown
  • SCCR
    100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27024000
  • ETIM 4.0
    EC001037
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Input name
    Control input and enable input
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Mains frequency
    50/60 Hz
  • Leakage current
    0 mA
  • Operating mode
    100% operating factor
  • Connection name
    Load circuit
  • Stripping length
    10 mm
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Degree of pollution
    2
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • Category code
    NLDX / NRNT
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 11.0
    27370905
  • ECLASS 4.0
    27021100
  • ECLASS 7.0
    27024002
  • Ambient temperature (operation)
    -25 °C ... 55 °C
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Rated control supply current IS
    60 mA
  • Switching threshold
    9.6 V (“0” signal)
  • Rated operating current Ie
    9 A (AC-51)
  • Cooling time
    20 min. (for auto reset)
  • Operate threshold
    > 60 A
  • ECLASS 10.0.1
    27370905
  • ETIM 2.0
    EC001037
  • ETIM 3.0
    EC001037
  • Width
    22.5 mm
  • Maximum altitude
    ≤ 2000 m
  • Type of protection
    Surge protection
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Output name
    Acknowledge output
  • Operating voltage range
    42 V AC ... 550 V AC
  • Load current range
    1.5 A ... 9 A
  • Response time
    < 0.5 s
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Minimum power dissipation
    0.88 W
  • Status display
    Yellow LED
  • Indication
    Red LED
  • Overvoltage category
    III
  • Certificate
    NLDX.E228652
  • Identification
    ≤ 3
  • Group installation
    20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
  • ECLASS 4.1
    27021100
  • ECLASS 6.0
    27024000
  • ECLASS 9.0
    27370905
  • ETIM 6.0
    EC001037
  • Depth
    114 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Note
    Confirmation: floating change-over contact, signal contact
  • Typical turn-off time
    < 30 ms
  • Contact type
    1 changeover contact
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Assembly instructions
    alignable, for spacing see derating
  • Operating voltage display
    Green LED
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 14
  • Rated surge voltage
    6 kV
  • Standards/regulations
    EN 60947-1
  • FLA
    7.6 A (480 V AC)
  • Horsepower ratings
    2 hp (208 V AC)
  • ECLASS 5.0
    27024000
  • ETIM 7.0
    EC001037

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2909568

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo