Phoenix Contact 2908855 Ex i measuring transducer supply conditioner and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active signals from the Ex area with electrical isolation to two loads. SIL 2 in accordance with IEC 61508, screw connectio
Phoenix Contact

Part#:2908855

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Ex i measuring transducer supply conditioner and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active signals from the Ex area with electrical isolation to two loads. SIL 2 in accordance with IEC 61508, screw connectio

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2908855 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    112.5 mm
  • Permissible humidity (operation)
    10 % ... 95 % (non-condensing)
  • Underload/overload signal range
    0 mA ... 24 mA (Extended transmission range for diagnostics)
  • Output ripple
    < 20 mVrms
  • Designation
    INMETRO
  • Vibration
    A
  • ECLASS 10.0.1
    27210120
  • ECLASS 5.0
    27210100
  • Signal output
    Signal conditioner operation
  • Nominal supply voltage
    24 V DC
  • Temperature
    B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27210100
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • DNV GL-Vibration
    A
  • Certificate
    DNV 18.0139 X
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27210100
  • ECLASS 7.0
    27210120
  • ETIM 7.0
    EC002653
  • DNV GL-EMC
    A
  • Humidity
    B
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Noise emission
    EN 61000-6-4
  • Nominal supply voltage range
    19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
  • Connection name
    Test socket
  • Maximum transmission error
    < 0.1 % (of final value)
  • Rated insulation voltage
    300 Vrms
  • Overvoltage category
    II
  • Protocols supported
    HART
  • Group
    IIC
  • Input voltage Ui
    ≤ 30 V
  • DNV GL-Temperature
    B
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Depth
    114.5 mm
  • Current input signal
    0 A ... 20 mA
  • Transmitter supply voltage
    > 16 V (20 mA)
  • Output behavior in the event of an error
    0 mA (Cable break in the input)
  • Connection method
    Screw connection
  • No. of channels
    1
  • Maximum temperature coefficient
    < 0.01 %/K
  • Max. output power Po
    587 mW
  • Max. external inductivity Lo
    10 µH
  • Max. internal inductance Li
    negligible
  • ATEX
     II (1) G [Ex ia Ga] IIC
  • Identification
    [Ex ia Ga] IIC
  • ECLASS 4.0
    27210100
  • ETIM 4.0
    EC002653
  • ETIM 6.0
    EC002653
  • Width
    12.5 mm
  • Maximum altitude
    ≤ 2000 m
  • Load/output load current output
    < 450 Ω (20 mA)
  • Supply voltage range
    19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
  • Screw thread
    M3
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • Max. external capacitance Co
    1 µF
  • Safety-related maximum voltage Um
    253 V AC (125 V DC)
  • Max. internal capacitance Ci
    negligible
  • DNV GL-Humidity
    B
  • ECLASS 11.0
    27210120
  • Ambient temperature (operation)
    -20 °C ... 60 °C (Any mounting position)
  • Signal input
    Signal conditioner operation
  • Power dissipation
    < 1.1 W (24 V DC / 20 mA)
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Max. diameter
    2 mm
  • Housing material
    PA 6.6-FR
  • Test voltage
    1.5 kV AC (50 Hz, 1 min.)
  • HART function
    Yes
  • Standards/regulations
    GB 3626.20
  • IECEx
    [Ex ia Ga] IIC
  • Voltage drop
    approx. 3.9 V (in input isolating amplifier operation)
  • Current output signal
    0 mA ... 20 mA (active)
  • Max. current consumption
    < 46 mA (24 V DC / 20 mA)
  • Stripping length
    7 mm
  • Torque
    0.5 Nm ... 0.6 Nm
  • Transmission error, typical
    < 0.05 % (of final value)
  • Interference emission
    EN 61000-6-4
  • Color
    gray
  • Electrical isolation
    375 V (Peak value in accordance with IEC/EN 60079-11)
  • Max. output current Io
    93 mA
  • Additional text
    and EN 61326
  • Input current Ii
    ≤ 150 mA
  • UL, USA/Canada
    Class I Div 2; IS for Class I, II, III Div 1
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 9.0
    27210120
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Degree of protection
    IP20 (not assessed by UL)
  • Polarization and surge protection
    Yes
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Conductor cross section AWG
    24 ... 14
  • Step response (10-90%)
    1.3 ms (Output 1, for jump 4 mA ... 20 mA, typical)
  • Status display
    Green LED (PWR supply voltage)
  • Degree of pollution
    2
  • Operation
    Signal conditioner operation
  • Max. output voltage Uo
    25.2 V
  • Conformance
    CE-compliant, additionally EN 61326
  • EMC
    A
  • ECLASS 6.0
    27210100

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo