Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2908716 Phoenix Contact Electrical Circuit Protection & Load Centers

Phoenix Contact 2908716 Multi-channel electronic circuit breaker that can be preconfigured, for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.
Phoenix Contact

Part#:2908716

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Multi-channel electronic circuit breaker that can be preconfigured, for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Circuit Protection & Load Centers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2908716 Phoenix Contact price in the box on the right side or send a quick quote.

2908716 Product Details

  • Height
    90 mm
  • Vibration (operation)
    10 Hz ... 57.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
  • Ambient temperature (storage/transport)
    -40 °C ... 70 °C
  • Degree of protection
    IP20
  • Number of positions
    1
  • Rated surge voltage
    0.5 kV
  • Efficiency
    > 99 %
  • Temperature derating
    24 A DC (at 60 °C)
  • Short-circuit switching capacity
    300 A
  • Shutdown time load circuit
    ≤ 10 ms (for short circuit > 2.0 x IN)
  • Conductor cross section AWG
    24 ... 12
  • DC operating current
    100 mA DC
  • Connection method
    Push-in connection
  • Ambient temperature (operation)
    -25 °C ... 60 °C
  • Altitude
    ≤ 3000 m up to 52 °C (amsl (above mean sea level))
  • Mounting type
    DIN rail: 35 mm
  • Fuse type
    electronic
  • Rated voltage
    24 V DC
  • Fail-safe element
    15 A DC (per output channel)
  • Closed circuit current I0
    typ. 33 mA
  • Dielectric strength
    max. 35 V DC (Load circuit)
  • Stripping length
    10 mm
  • DC operating voltage
    0 V DC ... 30 V DC
  • Channel LED yellow
    lit (Channel switched on, channel load > 80% )
  • Identification
    UL/C-UL Listed UL 508
  • ECLASS 11.0
    27140401
  • ECLASS 5.0
    27141100
  • UNSPSC 19.0
    39121410
  • UNSPSC 20.0
    39121410
  • Depth
    98 mm (incl. DIN rail 7.5 mm)
  • Shock (operation)
    30g (IEC 60068-2-27, Test Ea)
  • Protection class
    III
  • Operating voltage
    18 V DC ... 30 V DC
  • Feedback resistance
    max. 35 V DC
  • Waiting time after switch off of a channel
    5 s (at overload / short circuit)
  • MTBF (IEC 61709, SN 29500)
    8403361 h (at 25 °C with 21 % load)
  • Max. capacitive load load circuit
    45000 µF (Depending on the current setting and the short-circuit current available)
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Channel LED red
    lit (Channel switched off, over- or undervoltage active)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27141100
  • ECLASS 9.0
    27141116
  • UNSPSC 13.2
    39121410
  • Width
    36 mm
  • Humidity test
    96 h, 95 % RH, 40 °C
  • Color
    light grey RAL 7035
  • Degree of pollution
    2
  • Rated current IN
    max. 40 A DC (IN+)
  • Power dissipation
    typ. 0.8 W (No-load operation)
  • Tripping method
    E (electronic)
  • Undervoltage switch-off load circuit
    ≤ 17.8 V DC (active)
  • Connection name
    Main circuit OUT
  • Conductor cross section, flexible, with ferrule, with plastic sleeve
    0.25 mm² ... 1.5 mm²
  • Channel LED off
    off (Channel switched off)
  • Standards/specifications
    EN 61000-6-2 EMC – Immunity for industrial areas
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 7.0
    27141116
  • ETIM 6.0
    EC000899
  • Flammability rating according to UL 94
    V-0
  • Type
    DIN rail module, one-piece
  • Measuring tolerance I
    ± 15 %
  • Module initialization time
    1.6 s
  • Required backup fuse
    Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element.
  • Overvoltage switch-off shutdown load circuit
    ≥ 30.5 V DC (active)
  • Switching function
    N/O contact
  • Conductor cross section flexible, with ferrule without plastic sleeve
    0.25 mm² ... 2.5 mm²
  • Channel LED green
    lit (Channel switched on)
  • Designation
    UL approval
  • ECLASS 4.0
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 7.0
    EC000899
  • UNSPSC 21.0
    39121410
  • ECLASS 10.0.1
    27140401
  • ECLASS 5.1
    27141100
  • UNSPSC 18.0
    39121410

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2908716

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo