Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2908206 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2908206 Surge protection, consisting of protective plug and base element, with integrated status indicator for two signal wires with common reference potential, e.g., Digital IN/OUT. Indirect grounding via gas-filled surge arrester.
Phoenix Contact

Part#:2908206

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Surge protection, consisting of protective plug and base element, with integrated status indicator for two signal wires with common reference potential, e.g., Digital IN/OUT. Indirect grounding via gas-filled surge arrester.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2908206 Phoenix Contact price in the box on the right side or send a quick quote.

2908206 Product Details

  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • ECLASS 5.1
    27130801
  • UNSPSC 11
    39121610
  • UNSPSC 20.0
    39121620
  • Height
    105.8 mm
  • Permissible humidity (operation)
    5 % ... 95 %
  • Flammability rating according to UL 94
    V-0
  • IEC test classification
    C1
  • Operating effective current IC at UC
    ≤ 100 µA
  • Residual current IPE
    ≤ 1 µA
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    0.5 kA
  • Voltage protection level Up (line-signalground)
    ≤ 145 V (C1 - 1 kV/500 A)
  • Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω system
    typ. 440 kHz
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Max. total discharge current I total max (8/20) µs
    20 kA (1x)
  • Connection method
    Push-in connection
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27140201
  • ECLASS 7.0
    27130807
  • ETIM 3.0
    EC000943
  • UNSPSC 18.0
    39121620
  • UNSPSC 21.0
    39121620
  • Depth
    100 mm (incl. DIN rail 7.5 mm)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of protection
    IP20
  • Housing material
    PBT
  • Maximum continuous voltage UC
    15 V DC
  • Nominal discharge current In (8/20) µs (line-signal ground)
    5 kA
  • Voltage protection level Up (line-earth)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Response time tA (line-signalground)
    ≤ 1 ns
  • Response time tA (line-earth)
    ≤ 100 ns
  • Resistance per path
    1.65 Ω ±20 %
  • Pulse reset time (line-signalground)
    ≤ 30 ms
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 11.0
    27130807
  • ECLASS 5.0
    27130801
  • ETIM 6.0
    EC000943
  • UNSPSC 12.01
    39121610
  • UNSPSC 19.0
    39121620
  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Color
    traffic grey A RAL 7042
  • Type
    DIN rail module, two-section, divisible
  • Rated current
    600 mA (56 °C)
  • Pulse discharge current Iimp (10/350) µs (line-signalground)
    0.5 kA
  • Voltage protection level Up static (line-signalground)
    ≤ 35 V (C1 - 1 kV/500 A)
  • Input attenuation aE, asym.
    typ. 0.3 dB (≤ 140 kHz / 150 Ω)
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Stripping length
    8 mm
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27130801
  • ECLASS 6.0
    27130800
  • ETIM 4.0
    EC000943
  • ETIM 7.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 13.2
    39121620
  • Width
    6.2 mm +0.1 mm
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Mounting type
    DIN rail: TH 35 - 7.5 mm
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Nominal voltage UN
    12 V DC
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Voltage protection level Up static (line-earth)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Max. required back-up fuse
    630 mA (FF)
  • Capacity (line-signalground)
    typ. 5.2 nF
  • Pulse reset time (line-earth)
    ≤ 30 ms
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 10.0.1
    27130807
  • ECLASS 9.0
    27130807
  • UNSPSC 6.01
    30212010

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2908206

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo