Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2908200 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2908200 Surge protection, consisting of protective plug and base element, with integrated status indicator for a 2-wire floating signal circuit. Indirect grounding via gas-filled surge arrester.
Phoenix Contact

Part#:2908200

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Surge protection, consisting of protective plug and base element, with integrated status indicator for a 2-wire floating signal circuit. Indirect grounding via gas-filled surge arrester.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2908200 Phoenix Contact price in the box on the right side or send a quick quote.

2908200 Product Details

  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Degree of protection
    IP20
  • Mounting type
    DIN rail: TH 35 - 7.5 mm
  • Maximum continuous voltage UC
    55.2 V DC
  • Operating effective current IC at UC
    ≤ 5 µA
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    0.5 kA
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Voltage protection level Up (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 470 kHz / 150 Ω)
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-line)
    ≤ 700 ms
  • Max. total discharge current I total max (8/20) µs
    20 kA (1x)
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • Depth
    100 mm (incl. DIN rail 7.5 mm)
  • Permissible humidity (operation)
    5 % ... 95 %
  • Housing material
    PBT
  • IEC test classification
    C1
  • Nominal voltage UN
    48 V DC
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Nominal discharge current In (8/20) µs (line-signal ground)
    5 kA
  • Voltage protection level Up static (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Response time tA (line-line)
    ≤ 1 ns
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 1.8 MHz
  • Max. required back-up fuse
    160 mA DC (FF)
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 11.0
    27130807
  • ECLASS 5.0
    27130801
  • ETIM 3.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 12.01
    39121610
  • UNSPSC 20.0
    39121620
  • Width
    6.2 mm +0.1 mm
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Flammability rating according to UL 94
    V-0
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Residual current IPE
    ≤ 1 µA
  • Pulse discharge current Iimp (10/350) µs (line-line)
    0.5 kA
  • Voltage protection level Up (line-line)
    ≤ 180 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-line)
    ≤ 45 V (C1 - 1 kV/500 A)
  • Response time tA (line-signalground)
    ≤ 100 ns
  • Capacity (line-line)
    typ. 1.1 nF
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-earth)
    ≤ 30 ms
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27140201
  • ECLASS 6.0
    27130800
  • ETIM 4.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 18.0
    39121620
  • Height
    105.8 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Color
    traffic grey A RAL 7042
  • Type
    DIN rail module, two-section, divisible
  • Rated current
    160 mA DC (75 °C)
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Pulse discharge current Iimp (10/350) µs (line-signalground)
    0.5 kA
  • Voltage protection level Up (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Resistance per path
    1.65 Ω ±20 %
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-signalground)
    ≤ 1500 ms
  • Stripping length
    8 mm
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.1
    27130801
  • ECLASS 7.0
    27130807
  • ETIM 6.0
    EC000943
  • UNSPSC 11
    39121610
  • UNSPSC 19.0
    39121620
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27130801
  • ECLASS 9.0
    27130807
  • ETIM 7.0
    EC000943
  • UNSPSC 13.2
    39121620
  • UNSPSC 21.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2908200

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo