Ex i output signal conditioner, HART. Isolates and transmits 0/4…20 mA signals with intrinsic safety to a load in the Ex area. Galvanic 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3), Push-in connection.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2908062 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 116 mm
- Degree of protection IP20
- Line fault detection Response threshold of input current >0.2 mA
- Output ripple < 20 mVrms
- Max. current consumption < 45 mA (at 24 V DC / 20 mA)
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Connection name COMBICON connection
- Degree of pollution 2
- Overvoltage category II
- Ambient temperature (operation) -40 °C ... 45 °C
- Description Non-Ex applications (EN 61010-1)
- Rated insulation voltage 300 Vrms
- Signal output Current output intrinsically safe
- Transmission Behavior 1:1 to input signal
- Stripping length 8 mm
- Connection method Push-in connection
- Transmission error, typical ≤ 0.05 % (of final value)
- Step response (10-90%) < 140 µs (for 4 mA ... 20 mA step)
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Max. output voltage Uo 25.2 V
- Max. external inductivity Lo 100 µH
- Max. external capacitance Co 817 nF
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Max. voltage Um 60 V AC (non-intrinsically-safe circuit)
- Input impedance > 1 MΩ (If there is a line fault)
- Non-load voltage ≤ 27 V
- Power consumption ≤ 1.1 W (at 24 V DC / 20 mA)
- Maximum transmission error 0.1 % (of final value)
- Temperature coefficient, typical ≤ 0.005 %/K
- Interference emission EN 61000-6-4
- Color gray
- Protocols supported HART
- Group IIC
- Conformance CE-compliant, additionally EN 61326
- Temperature B
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27210100
- ETIM 6.0 EC002653
- Depth 114.5 mm
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Current input signal 0 mA ... 20 mA (Function (short-circuit detection off))
- Voltage drop < 2.4 V (at 20 mA)
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Max. diameter 2 mm
- Status display Green LED (supply voltage)
- Designation Systematic Capability
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Max. internal capacitance Ci negligible
- Additional text and EN 61326
- Width 12.5 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Altitude ≤ 2000 m
- Current output signal 0 mA ... 20 mA (Function (short-circuit detection off))
- Nominal supply voltage 24 V DC
- Power dissipation < 0.8 W (at 24 V DC / 20 mA)
- Conductor cross section AWG 24 ... 16
- Maximum temperature coefficient 0.01 %/K
- Housing material PA 6.6-FR
- HART function Yes
- Max. output power Po 586 mW
- Noise emission EN 61000-6-4
- Certificate DNV GL TAA00000AG
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.1 27210100
- ETIM 7.0 EC002653
- Max. output current Io 93 mA
- Standards/regulations GB 3836.1
- Identification 3
- ECLASS 4.0 27210100
- ECLASS 9.0 27210120
- Max. internal inductance Li negligible
- Safety-related maximum voltage Um 253 V AC (125 V DC)
- EMC B
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 5.0 27210100
- ETIM 4.0 EC002653
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Humidity B
- Vibration A
- ECLASS 10.0.1 27210120
- ECLASS 11.0 27210120
- ECLASS 6.0 27210100
- ECLASS 7.0 27210120
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨