About the product: Active QUINT single redundancy module for DIN rail mounting, input: 12 - 24 V DC, output: 12 - 24 V DC/1 x 40 A, incl. mounted UTA 107/30 universal DIN rail adapter
About the category: A redundancy module is used to decouple two power supplies and ensures the high availability and productivity of your system. A redundant power supply is particularly necessary in applications with stringent demands regarding operational safety.
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 2907752 Phoenix Contact price in the box on the right side or send a quick quote.
2907752 Product Details
- Height with alternative assembly 130 mm
- Depth with alternative assembly 35 mm
- Degree of pollution 2
- Current consumption 40 A
- Static Boost (IStat.Boost) 45 A
- Selective Fuse Breaking (ISFB) 215 A (15 ms)
- Connection in series No
- Conductor cross section solid max. 1.5 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
- Additional text 60 s
- Test field strength 30 A/m
- Surge voltage load (surge) EN 61000-4-5
- REACh SVHC Lead 7439-92-1
- UNSPSC 13.2 39121004
- Depth 125 mm
- Installation distance top/bottom 40 mm / 20 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (operation) -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Dynamic Boost (IDyn.Boost) 60 A (5 s)
- Efficiency typ. 99.1 % (12 V DC)
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- EMC requirements for noise emission EN 61000-6-3
- Width with alternative assembly 122 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 8 V DC ... 30 V DC
- Nominal output current (IN) 40 A
- Net weight 0.55 kg
- Mounting position horizontal DIN rail NS 35, EN 60715
- Connection method Push-in connection
- Conductor cross section AWG min. 24
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Noise emission EN 55016
- Electrostatic discharge EN 61000-4-2
- Comments Criterion A
- Fast transients (burst) EN 61000-4-4
- Power frequency magnetic field EN 61000-4-8
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 9.0 27371010
- Height 130 mm
- Degree of protection IP20
- Climatic class 3K3 (in acc. with EN 60721)
- Nominal input current 40 A (-40 °C ... 60 °C)
- Derating 60 °C ... 70 °C (2.5%/K)
- MTBF (IEC 61709, SN 29500) > 25297000 h (25 °C)
- Protection class III
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 16
- Screw thread M4
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Shipbuilding approval DNV GL
- Conducted noise emission EN 55016
- DNV GL noise radiation Class B
- Contact discharge 8 kV (Test Level 4)
- Discharge in air 15 kV (Test Level 4)
- Output 1 kV (Test Level 2 - symmetrical)
- I/O/S asymmetrical
- Conducted interference EN 61000-4-6
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 10.0.1 27371010
- ETIM 6.0 EC002540
- Width 32 mm
- Installation distance right/left 0 mm / 0 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 12 V DC ... 24 V DC
- Output voltage range 8 V DC ... 30 V DC
- Power loss nominal load max. 6.5 W (IOUT = 40 A)
- Housing material Aluminum / stainless steel
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section flexible max. 1.5 mm²
- Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
- Standard - Safe isolation DIN VDE 0100-410
- UL approvals UL/C-UL listed UL 508
- DNV GL conducted interference Class A
- Frequency range 0.15 MHz ... 80 MHz
- Input 1 kV (Test Level 4 - symmetrical)
- Voltage 10 V (Test Level 3)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27371010
- UNSPSC 19.0 39121004
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field EN 61000-4-3
- Signal 1 kV (Test Level 2 - asymmetrical)
- Frequency 16.67 Hz
- ECLASS 5.1 27242213
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨