2906877 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2906877
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Checking verified in-stock parts...
About the product: Universally configurable temperature limit value switch with two transistor outputs for the connection of 2, 3, and 4-conductor resistance thermometers and thermocouples. Configurable via DIP switch or software, push-in connection technology
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 2906877 Phoenix Contact price in the box on the right side or send a quick quote.
2906877 Product Details
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Degree of protection IP20 (not assessed by UL)
- Max. permissible overall conductor resistance ≤ 25 Ω (Per line, RTD in 3- or 4-conductor technology)
- Maximum switching voltage 30 V DC
- Power consumption 350 mW
- Conductor cross section AWG 24 ... 12 (flexible)
- Degree of pollution 2
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- Mounting position any
- ATEX II 3 G Ex nA IIC T4 Gc X
- DNV GL-Humidity B
- Identification UL 508 Listed
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.0 27210100
- ETIM 6.0 EC002654
- UNSPSC 7.0901 39121008
- UNSPSC 18.0 39121008
- UNSPSC 13.2 39121008
- Ambient temperature (operation) -40 °C ... 70 °C
- Available input sources Thermocouples
- Connection technology 2-, 3-, 4-conductor
- Output name Switching output
- Number of outputs 2
- Typical current consumption 20 mA (12 V DC)
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Conductor cross section solid 0.2 mm² ... 2.5 mm² (with ferrule)
- Maximum temperature coefficient 0.01 %/K
- Rated insulation voltage 300 V
- Color gray
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- EMC A
- REACh SVHC Lead 7439-92-1
- ECLASS 6.0 27210100
- ECLASS 7.0 27210122
- UNSPSC 11 39121008
- Height 109.81 mm
- Number of inputs 1
- Linear mV signal range -500 mV ... 500 mV
- Max. switching current 100 mA (30 V)
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- Conformance CE-compliant
- UL, USA/Canada UL 508 Listed
- DNV GL-EMC A
- Temperature B
- ECLASS 11.0 27210122
- ECLASS 4.0 27210100
- ETIM 4.0 EC002654
- UNSPSC 19.0 39121008
- Width 6.2 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors
- Contact type 2 N/O contacts
- Nominal supply voltage 24 V DC
- Connection method Push-in connection
- No. of channels 1
- Status display Yellow LED (switching output)
- Noise emission EN 61000-6-4
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- DNV GL-Vibration A
- Certificate DNV GL TAA000021E
- Vibration A
- ECLASS 10.0.1 27210122
- ECLASS 9.0 27210122
- UNSPSC 6.01 30211506
- UNSPSC 21.0 39121008
- Depth 119.2 mm
- Maximum altitude ≤ 2000 m
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Sensor input current approx. 200 µA
- Linear resistance measuring range 0 Ω ... 4000 Ω
- Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
- Stripping length 10 mm
- Switching point accuracy < 0.1 %
- Overvoltage category II
- Electromagnetic compatibility Conformance with EMC directive
- Housing material PBT
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- DNV GL-Temperature B
- Designation Shipbuilding approval
- Humidity B
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 4.1 27210100
- ECLASS 5.1 27210100
- ETIM 7.0 EC002654
- UNSPSC 12.01 39121008
- UNSPSC 20.0 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨