Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2906790 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2906790 Surge protection, consisting of protective plug and base element, with integrated status indicator and disconnect knife for a 2-wire floating signal circuit, e.g., 0(4) ... 20 mA current loop. Indirect grounding via gas discharge tube, HART-compatible.
Phoenix Contact

Part#:2906790

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Surge protection, consisting of protective plug and base element, with integrated status indicator and disconnect knife for a 2-wire floating signal circuit, e.g., 0(4) ... 20 mA current loop. Indirect grounding via gas discharge tube, HART-compatible.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2906790 Phoenix Contact price in the box on the right side or send a quick quote.

2906790 Product Details

  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Mounting type
    DIN rail: TH 35 - 7.5 mm
  • Maximum continuous voltage UC
    30 V DC
  • Residual current IPE
    ≤ 1 µA
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    0.5 kA
  • Voltage protection level Up static (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Response time tA (line-line)
    ≤ 1 ns
  • Capacity (line-line)
    typ. 2.2 nF
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Max. total discharge current I total max (8/20) µs
    20 kA (1x)
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 4.1
    27130801
  • ECLASS 7.0
    27130807
  • ETIM 3.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 18.0
    39121620
  • UNSPSC 21.0
    39121620
  • Width
    6.2 mm +0.1 mm
  • Permissible humidity (operation)
    5 % ... 95 %
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Rated current
    600 mA (56 °C)
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Voltage protection level Up (line-line)
    ≤ 200 V (C1 - 1 kV/500 A)
  • Response time tA (line-signalground)
    ≤ 100 ns
  • Resistance per path
    1.65 Ω ±20 %
  • Pulse reset time (line-earth)
    ≤ 30 ms
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 11.0
    27130807
  • ECLASS 9.0
    27130807
  • ETIM 6.0
    EC000943
  • UNSPSC 12.01
    39121610
  • Depth
    100 mm (incl. DIN rail 7.5 mm)
  • Housing material
    PBT
  • Color
    traffic grey A RAL 7042
  • IEC test classification
    C1
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Nominal discharge current In (8/20) µs (line-signal ground)
    5 kA
  • Voltage protection level Up (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 940 kHz
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27130801
  • ETIM 4.0
    EC000943
  • UNSPSC 13.2
    39121620
  • UNSPSC 19.0
    39121620
  • Height
    105.8 mm
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Flammability rating according to UL 94
    V-0
  • Nominal voltage UN
    24 V DC
  • Pulse discharge current Iimp (10/350) µs (line-line)
    0.5 kA
  • Voltage protection level Up (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-line)
    ≤ 700 ms
  • Pulse reset time (line-signalground)
    ≤ 1500 ms
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.0
    27130801
  • UNSPSC 7.0901
    39121610
  • UNSPSC 20.0
    39121620
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of protection
    IP20
  • Type
    DIN rail module, two-section, divisible
  • Operating effective current IC at UC
    ≤ 5 µA
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Pulse discharge current Iimp (10/350) µs (line-signalground)
    0.5 kA
  • Voltage protection level Up static (line-line)
    ≤ 50 V (C1 - 1 kV/500 A)
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 250 kHz / 150 Ω)
  • Max. required back-up fuse
    630 mA (FF)
  • Stripping length
    8 mm
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27140201
  • ECLASS 6.0
    27130800
  • ETIM 2.0
    EC000943
  • ETIM 7.0
    EC000943
  • UNSPSC 11
    39121610

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2906790

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo