2906781 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2906781 Surge protection, consisting of protective plug and base element, with integrated status indicator and disconnect knife for a 2-wire floating signal circuit, e.g., 0(4) ... 20 mA current loop. Indirect grounding via gas discharge tube, HART-compatible.
Phoenix Contact

Part#:2906781

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Surge protection, consisting of protective plug and base element, with integrated status indicator and disconnect knife for a 2-wire floating signal circuit, e.g., 0(4) ... 20 mA current loop. Indirect grounding via gas discharge tube, HART-compatible.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2906781 Phoenix Contact price in the box on the right side or send a quick quote.

2906781 Product Details

  • Height
    105.8 mm
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Flammability rating according to UL 94
    V-0
  • Type
    DIN rail module, two-section, divisible
  • Residual current IPE
    ≤ 1 µA
  • Operating effective current IC at UC
    ≤ 5 µA
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    0.5 kA
  • Voltage protection level Up (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Response time tA (line-signalground)
    ≤ 100 ns
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-earth)
    ≤ 30 ms
  • Tightening torque
    0.5 Nm ... 0.6 Nm
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27140201
  • ECLASS 9.0
    27130807
  • ETIM 4.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • Screw thread
    M3
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 5.0
    27130801
  • ETIM 2.0
    EC000943
  • ETIM 7.0
    EC000943
  • UNSPSC 13.2
    39121620
  • Width
    6.2 mm +0.1 mm
  • Color
    traffic grey A RAL 7042
  • Mounting type
    DIN rail: TH 35 - 7.5 mm
  • Nominal voltage UN
    24 V DC
  • Nominal discharge current In (8/20) µs (line-signal ground)
    5 kA
  • Pulse discharge current Iimp (10/350) µs (line-signalground)
    0.5 kA
  • Voltage protection level Up (line-line)
    ≤ 200 V (C1 - 1 kV/500 A)
  • ETIM 3.0
    EC000943
  • Voltage protection level Up static (line-line)
    ≤ 50 V (C1 - 1 kV/500 A)
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 250 kHz / 150 Ω)
  • Capacity (line-line)
    typ. 2.2 nF
  • Pulse reset time (line-line)
    ≤ 700 ms
  • Connection method
    Screw connection
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 11.0
    27130807
  • ECLASS 6.0
    27130800
  • ETIM 6.0
    EC000943
  • UNSPSC 12.01
    39121610
  • UNSPSC 18.0
    39121620
  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of protection
    IP20
  • IEC test classification
    C1
  • Maximum continuous voltage UC
    30 V DC
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Pulse discharge current Iimp (10/350) µs (line-line)
    0.5 kA
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Response time tA (line-line)
    ≤ 1 ns
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 940 kHz
  • Max. required back-up fuse
    630 mA (FF)
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Max. total discharge current I total max (8/20) µs
    20 kA (1x)
  • Stripping length
    8 mm
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27130801
  • UNSPSC 6.01
    30212010
  • UNSPSC 19.0
    39121620
  • Depth
    100 mm (incl. DIN rail 7.5 mm)
  • Permissible humidity (operation)
    5 % ... 95 %
  • Housing material
    PBT
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Rated current
    600 mA (56 °C)
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Voltage protection level Up (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Resistance per path
    1.65 Ω ±20 %
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-signalground)
    ≤ 1500 ms
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.1
    27130801
  • ECLASS 7.0
    27130807
  • UNSPSC 11
    39121610
  • UNSPSC 21.0
    39121620
  • UNSPSC 20.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2906781

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo