Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2906772 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2906772 Surge protection with integrated status indicator and knife disconnection for a 2-wire floating signal circuit, e.g., 0(4)...20 mA current loop. Indirect grounding via gas discharge tube, HART-compatible.
Phoenix Contact

Part#:2906772

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Surge protection with integrated status indicator and knife disconnection for a 2-wire floating signal circuit, e.g., 0(4)...20 mA current loop. Indirect grounding via gas discharge tube, HART-compatible.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2906772 Phoenix Contact price in the box on the right side or send a quick quote.

2906772 Product Details

  • Depth
    83.5 mm (incl. DIN rail 7.5 mm)
  • Permissible humidity (operation)
    5 % ... 95 %
  • Mounting type
    DIN rail: TH 35 - 7.5 mm
  • Residual current IPE
    ≤ 1 µA
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Pulse discharge current Iimp (10/350) µs (line-line)
    0.5 kA
  • Response time tA (line-signalground)
    ≤ 100 ns
  • Resistance per path
    1.65 Ω ±20 %
  • Height
    105.8 mm
  • Width
    6.2 mm +0.1 mm
  • Color
    traffic grey A RAL 7042
  • IEC test classification
    C1
  • Rated current
    600 mA (40 °C)
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Voltage protection level Up (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Response time tA (line-line)
    ≤ 1 ns
  • Response time tA (line-earth)
    ≤ 100 ns
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • ECLASS 7.0
    27130807
  • UNSPSC 12.01
    39121610
  • UNSPSC 18.0
    39121620
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Housing material
    PBT
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Nominal voltage UN
    24 V DC
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    0.5 kA
  • Voltage protection level Up (line-line)
    ≤ 55 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Max. required back-up fuse
    630 mA (FF)
  • Pulse reset time (line-earth)
    ≤ 30 ms
  • Connection method
    Push-in connection
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.1
    27130801
  • ETIM 7.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 13.2
    39121620
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Flammability rating according to UL 94
    V-0
  • Type
    DIN rail module, one-piece
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Pulse discharge current Iimp (10/350) µs (line-signalground)
    0.5 kA
  • Voltage protection level Up static (line-line)
    ≤ 50 V (C1 - 1 kV/500 A)
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 940 kHz
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 250 kHz / 150 Ω)
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-signalground)
    ≤ 1500 ms
  • Stripping length
    8 mm
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27130801
  • ECLASS 5.0
    27130801
  • ECLASS 9.0
    27130807
  • UNSPSC 11
    39121610
  • UNSPSC 20.0
    39121620
  • UNSPSC 21.0
    39121620
  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Degree of protection
    IP20
  • Maximum continuous voltage UC
    30 V DC
  • Operating effective current IC at UC
    ≤ 5 µA
  • Nominal discharge current In (8/20) µs (line-signal ground)
    5 kA
  • Voltage protection level Up (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Capacity (line-line)
    typ. 2.2 nF
  • Pulse reset time (line-line)
    ≤ 700 ms
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 4.0
    27140201
  • ETIM 3.0
    EC000943
  • ETIM 4.0
    EC000943
  • UNSPSC 19.0
    39121620
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Max. total discharge current I total max (8/20) µs
    20 kA (1x)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 11.0
    27130807
  • ECLASS 6.0
    27130800
  • ETIM 6.0
    EC000943
  • UNSPSC 7.0901
    39121610

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2906772

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo