2906738 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2906738 Surge protection, consisting of protective plug and base element, with integrated status indicator and disconnect knife for a 2-wire floating signal circuit, e.g., 0(4) ... 20 mA current loop, HART-compatible.
Phoenix Contact

Part#:2906738

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Surge protection, consisting of protective plug and base element, with integrated status indicator and disconnect knife for a 2-wire floating signal circuit, e.g., 0(4) ... 20 mA current loop, HART-compatible.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2906738 Phoenix Contact price in the box on the right side or send a quick quote.

2906738 Product Details

  • ECLASS 5.0
    27130801
  • Depth
    100 mm (incl. DIN rail 7.5 mm)
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Type
    DIN rail module, two-section, divisible
  • IEC test classification
    C1
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Voltage protection level Up (line-earth)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Response time tA (line-line)
    ≤ 1 ns
  • Pulse reset time (line-line)
    ≤ 700 ms
  • Tightening torque
    0.5 Nm ... 0.6 Nm
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Housing material
    PBT
  • Mounting type
    DIN rail: TH 35 - 7.5 mm
  • Nominal voltage UN
    24 V DC
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    0.5 kA
  • Voltage protection level Up (line-line)
    ≤ 200 V (C1 - 1 kV/500 A)
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 940 kHz
  • Max. required back-up fuse
    630 mA (FF)
  • Screw thread
    M3
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27140201
  • ECLASS 4.1
    27130801
  • ECLASS 7.0
    27130807
  • UNSPSC 11
    39121610
  • UNSPSC 21.0
    39121620
  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Degree of protection
    IP20
  • Rated current
    600 mA (56 °C)
  • Residual current IPE
    ≤ 1 µA
  • Voltage protection level Up static (line-line)
    ≤ 50 V (C1 - 1 kV/500 A)
  • Resistance per path
    1.65 Ω ±20 %
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Max. total discharge current I total max (8/20) µs
    20 kA (1x)
  • Stripping length
    8 mm
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 9.0
    27130807
  • ETIM 2.0
    EC000943
  • ETIM 7.0
    EC000943
  • UNSPSC 20.0
    39121620
  • Height
    105.8 mm
  • Permissible humidity (operation)
    5 % ... 95 %
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Operating effective current IC at UC
    ≤ 5 µA
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Response time tA (line-earth)
    ≤ 100 ns
  • Capacity (line-line)
    typ. 2.2 nF
  • Pulse reset time (line-earth)
    ≤ 1500 ms
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • ECLASS 11.0
    27130807
  • ECLASS 6.0
    27130800
  • ETIM 4.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 13.2
    39121620
  • Width
    6.2 mm +0.1 mm
  • Color
    traffic grey A RAL 7042
  • Flammability rating according to UL 94
    V-0
  • Maximum continuous voltage UC
    30 V DC
  • Pulse discharge current Iimp (10/350) µs (line-line)
    0.5 kA
  • Voltage protection level Up static (line-earth)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 250 kHz / 150 Ω)
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Connection method
    Screw connection
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.1
    27130801
  • ETIM 3.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 18.0
    39121620
  • ETIM 6.0
    EC000943
  • UNSPSC 12.01
    39121610
  • UNSPSC 19.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2906738

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo