Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2906164 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2906164 Limit value switch with Ex i input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, screw connection.
Phoenix Contact

Part#:2906164

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Limit value switch with Ex i input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, screw connection.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2906164 Phoenix Contact price in the box on the right side or send a quick quote.

2906164 Product Details

  • Width
    12.5 mm
  • Maximum altitude
    ≤ 2000 m
  • Current input signal
    0.2 mA ... 20 mA
  • Switching hysteresis
    off: approx. 0.5 %, on: approx. 1 %
  • Mechanical service life
    ≤ 107 cycles
  • Supply voltage range
    9.6 V DC ... 30 V DC (12 V DC ... 24 V DC (-20 % ... +25 %))
  • Screw thread
    M3
  • Conductor cross section AWG
    24 ... 14
  • Maximum transmission error
    0.1 %
  • Status display
    Green LED (supply voltage, PWR)
  • Housing material
    PA 6.6-FR
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • Max. internal inductance Li
    negligible
  • Max. output current Io
    0 mA (Current input)
  • Noise emission
    EN 61000-6-4
  • Certificate
    TÜV Rheinland 968/FSP 1481.00/17
  • Vibration
    A
  • Depth
    114.5 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Input resistance of voltage input
    > 100 kΩ
  • Input resistance current input
    < 28 Ω
  • Contact material
    AgSnO2, hard gold-plated
  • Power dissipation
    < 0.9 W
  • Connection method
    Screw connection
  • Max. diameter
    2 mm
  • Overvoltage category
    II
  • Electrical isolation
    375 V (Peak value in accordance with IEC/EN 60079-11)
  • Input voltage Ui
    30 V (Current and voltage input)
  • Max. output voltage Uo
    0 V DC (Current input)
  • Group
    IIC
  • Identification
    3
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27210100
  • ECLASS 7.0
    27210120
  • ETIM 4.0
    EC002653
  • Ambient temperature (operation)
    -20 °C ... 65 °C (Any mounting position)
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Signal input
    Intrinsically safe
  • Max. switching current
    ≤ 4 A AC (cos phi = 1)
  • Power consumption
    ≤ 1.2 W
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Degree of pollution
    2
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Input current Ii
    120 mA (Current and voltage input)
  • Max. output power Po
    0 mW (Current input)
  • Additional text
    two-channel
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 11.0
    27210120
  • ETIM 7.0
    EC002653
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Voltage input signal
    0.1 V ... 10 V
  • Output name
    Relay output
  • Contact type
    1 changeover contact
  • Max. current consumption
    90 mA (10 V DC)
  • Stripping length
    7 mm
  • Torque
    0.5 Nm ... 0.6 Nm
  • Maximum temperature coefficient
    0.01 %/K
  • Interference emission
    EN 61000-6-4
  • Rated insulation voltage
    300 Vrms
  • Test voltage
    2.5 kV AC (50 Hz, 1 min.)
  • Max. internal capacitance Ci
    75 nF (for current input)
  • Safety-related maximum voltage Um
    253 V AC
  • Max. external inductivity Lo
    1 mH
  • Temperature
    B
  • ECLASS 10.0.1
    27210120
  • ECLASS 4.0
    27210100
  • ECLASS 5.0
    27210100
  • ECLASS 5.1
    27210100
  • Height
    112.5 mm
  • Degree of protection
    IP20
  • Line fault detection
    Break U < 50 mV, I < 0.1 mA
  • Typical current consumption
    38 mA (24 V DC)
  • Nominal supply voltage
    24 V DC
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Connection name
    Test socket
  • Step response (0–99%)
    ≤ 22 ms
  • Designation
    Systematic Capability
  • Input power Pi
    900 mW (Current and voltage input)
  • Max. external capacitance Co
    35 µF
  • Standards/regulations
    GB 3626.20
  • Humidity
    B
  • EMC
    A
  • ECLASS 6.0
    27210100
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 9.0
    27210120
  • ETIM 6.0
    EC002653

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2906164

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo