2906058 Phoenix Contact Electrical Safety Devices

Phoenix Contact 2906058 Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 0.6 A output current, emergency stop function, adjustable overload shutdown, higher transient voltage strength, and push-in connection.
Phoenix Contact

Part#:2906058

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 0.6 A output current, emergency stop function, adjustable overload shutdown, higher transient voltage strength, and push-in connection.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2906058 Phoenix Contact price in the box on the right side or send a quick quote.

2906058 Product Details

  • Depth
    114 mm
  • Ambient temperature (operation)
    5 °C ... 70 °C (observe derating)
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Typical turn-off time
    < 30 ms
  • Output name
    Acknowledge output
  • Leakage current
    0 mA
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Assembly instructions
    alignable, for spacing see derating
  • Connection name
    Load circuit
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Width
    22.5 mm
  • Degree of protection
    IP20
  • Type of protection
    Surge protection
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Mains frequency
    50/60 Hz
  • Load current range
    75 mA ... 600 mA (see to derating)
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Operating voltage display
    Green LED
  • Indication
    Red LED
  • Degree of pollution
    2
  • Designation
    Category (ISO 13849)
  • SCCR
    100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • Certificate
    NLDX.E228652
  • Height
    107.5 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Input name
    Control input right/left
  • Rated actuating current IC
    5 mA
  • Operating voltage range
    42 V AC ... 550 V AC
  • Cooling time
    20 min.
  • Note
    Confirmation: floating change-over contact, signal contact
  • Maximum power dissipation
    1.5 W
  • Minimum power dissipation
    1.1 W
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Conductor cross section AWG
    24 ... 14
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • FLA
    0.6 A (480 V AC)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27370905
  • ECLASS 7.0
    27024002
  • ECLASS 6.0
    27024000
  • ETIM 7.0
    EC001037
  • UNSPSC 18.0
    25173902
  • UNSPSC 21.0
    25173902
  • Maximum altitude
    ≤ 2000 m
  • Rated control supply current IS
    40 mA
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10A
  • Switching capacity according to IEC 60947-5-1
    3 A (230 V, AC15)
  • Mounting type
    DIN rail mounting
  • Status display
    Yellow LED
  • Connection method
    Push-in connection
  • Rated surge voltage
    6 kV
  • Identification
    ≤ 3
  • Group installation
    20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
  • Category code
    NLDX / NRNT
  • ECLASS 4.0
    27021100
  • ECLASS 5.0
    27024000
  • ETIM 2.0
    EC001037
  • UNSPSC 20.0
    25173902
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Rated actuating voltage UC
    24 V DC
  • Switching threshold
    9.6 V (“0” signal)
  • Rated operating voltage Ue
    500 V AC
  • Rated operating current Ie
    0.6 A (AC-51)
  • Contact type
    1 changeover contact
  • Motor starter type
    Reversing starter
  • Operating mode
    100% operating factor
  • Stripping length
    10 mm
  • Rated insulation voltage
    500 V
  • Standards/regulations
    IEC 60947-1
  • Overvoltage category
    III
  • Additional text
    Safe shutdown
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27024000
  • ETIM 3.0
    EC001037
  • ETIM 6.0
    EC001037
  • UNSPSC 19.0
    25173902
  • ECLASS 10.0.1
    27370905
  • ECLASS 4.1
    27021100
  • ECLASS 9.0
    27370905
  • ETIM 4.0
    EC001037
  • UNSPSC 13.2
    25173902

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo