Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2905151 Phoenix Contact Electrical Safety Devices

Phoenix Contact 2905151 Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC, and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3/PL e and screw connection, DIN rail connector provided.
Phoenix Contact

Part#:2905151

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC, and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3/PL e and screw connection, DIN rail connector provided.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2905151 Phoenix Contact price in the box on the right side or send a quick quote.

2905151 Product Details

  • Depth
    114 mm
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Type of protection
    Surge protection
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Typical turn-off time
    < 30 ms
  • Operating voltage range
    42 V AC ... 550 V AC
  • Cooling time
    20 min. (for auto reset)
  • Leakage current
    0 mA
  • Mounting type
    DIN rail mounting
  • Assembly instructions
    alignable, for spacing see derating
  • Indication
    Red LED
  • Stripping length
    8 mm
  • Conductor cross section AWG
    24 ... 14
  • Designation
    Category (ISO 13849)
  • Identification
    ≤ 3
  • Category code
    NLDX / NRNT
  • ECLASS 5.0
    27024000
  • ECLASS 4.1
    27021100
  • Width
    22.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Rated control circuit supply voltage US
    24 V DC
  • Input name
    Enable input
  • Rated actuating current IC
    7 mA
  • Output name
    AC output
  • Rated operating voltage Ue
    500 V AC
  • Response time
    < 0.5 s
  • Motor starter type
    Reversing starter
  • Operating voltage display
    Green LED
  • Connection method
    Screw connection
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Rated insulation voltage
    550 V
  • Certificate
    NLDX.E228652
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • Group installation
    20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 10.0.1
    27370905
  • ECLASS 6.0
    27024000
  • ETIM 6.0
    EC001037
  • ETIM 4.0
    EC001037
  • UNSPSC 19.0
    25173902
  • Height
    107 mm
  • Maximum altitude
    ≤ 2000 m
  • Rated control supply current IS
    60 mA
  • Switching threshold
    9.6 V (“0” signal)
  • Rated operating current Ie
    0.6 A (AC-51)
  • Mains frequency
    50/60 Hz
  • Load current range
    75 mA ... 600 mA (see to derating)
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Maximum power dissipation
    2.5 W
  • Status display
    Yellow LED
  • Connection name
    Load circuit
  • Torque
    0.5 Nm ... 0.6 Nm
  • Overvoltage category
    III
  • Standards/regulations
    IEC 60947-1
  • Additional text
    Safe shutdown
  • SCCR
    100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • ECLASS 11.0
    27370905
  • ECLASS 9.0
    27370905
  • ETIM 3.0
    EC001037
  • UNSPSC 18.0
    25173902
  • UNSPSC 20.0
    25173902
  • Ambient temperature (operation)
    -5 °C ... 60 °C (observe derating)
  • Degree of protection
    IP20
  • Note
    The enable input is compatible with signals with blanking (semiconductor output signals with test pulse with max. 3 ms duration),unblanking pulses of max. 4 ms are tolerated without adversely affecting the safety function.
  • Rated actuating voltage UC
    24 V DC
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10
  • Operate threshold
    > 10 A
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Operating mode
    100% operating factor
  • Minimum power dissipation
    0.88 W
  • Screw thread
    M3
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Rated surge voltage
    6 kV
  • Degree of pollution
    2
  • FLA
    0.6 A (480 V AC)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27021100
  • ECLASS 7.0
    27024002
  • ECLASS 5.1
    27024000
  • UNSPSC 13.2
    25173902
  • UNSPSC 21.0
    25173902
  • ETIM 2.0
    EC001037
  • ETIM 7.0
    EC001037

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2905151

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo