2905012 Phoenix Contact DC/DC Converters

Phoenix Contact 2905012 Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (selective fuse breaking) technology, input: 96 - 110 V DC, output: 24 V DC/10 A
Phoenix Contact

Part#:2905012

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (selective fuse breaking) technology, input: 96 - 110 V DC, output: 24 V DC/10 A

About the category: DC-DC Converters convert a direct current voltage input into a different direct current voltage output

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2905012 Phoenix Contact price in the box on the right side or send a quick quote.

2905012 Product Details

  • Width
    48 mm
  • Height with alternative assembly
    130 mm
  • Installation distance right/left
    0 mm / 0 mm (≤ 70 °C)
  • Ambient temperature (start-up type tested)
    -40 °C
  • Degree of protection
    IP20
  • Degree of pollution
    2
  • Input voltage range
    67.2 V DC ... 154 V DC
  • Input fuse
    10 A 150 V DC (internal (device protection))
  • Protective circuit/component
    Varistor
  • POWER BOOST (IBoost)
    12.5 A (-40°C ... 40°C permanent, UOUT = 24 V DC )
  • Protection against overvoltage at the output (OVP)
    < 35 V DC
  • Max. capacitive load
    unlimited
  • Residual ripple
    < 20 mVPP
  • Protection class
    I
  • Conductor cross section flexible min.
    0.2 mm²
  • Screw thread
    M3
  • Contact discharge
    8 kV (Test Level 4)
  • Net weight
    0.9 kg
  • Connection method
    Screw connection
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG max.
    12
  • Standard - Electrical safety
    EN 60950-1/VDE 0805 (SELV)
  • UL approvals
    UL/C-UL listed UL 508
  • Electrostatic discharge
    EN 61000-4-2
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 5.1
    27210900
  • ECLASS 9.0
    27210901
  • UNSPSC 20.0
    39121041
  • Depth
    125 mm
  • Depth with alternative assembly
    51 mm
  • Installation distance top/bottom (active)
    50 mm / 50 mm (≤ 70 °C)
  • Installation distance top/bottom
    50 mm / 50 mm (≤ 70 °C)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Current consumption
    3.5 A (96 V DC)
  • Mains buffering time
    typ. 10 ms (96 V DC)
  • Nominal output voltage
    24 V DC ±1 %
  • Nominal output current (IN)
    10 A (-40 °C ... 60 °C)
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Feedback voltage resistance
    35 V DC
  • Power loss nominal load max.
    22 W (UIN 110 V DC)
  • Insulation voltage input/output
    1.5 kV (type test)
  • Conductor cross section flexible max.
    2.5 mm²
  • EMC requirements for noise emission
    EN 61000-6-3
  • Rail applications
    EN 50121-4
  • Frequency range
    0.15 MHz ... 80 MHz
  • Input
    2 kV (Test Level 4 - symmetrical)
  • Voltage
    10 V (Test Level 3)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27210900
  • ETIM 6.0
    EC002046
  • UNSPSC 21.0
    39121041
  • Height
    130 mm
  • Width with alternative assembly
    122 mm
  • Installation distance right/left (active)
    15 mm / 15 mm (≤ 70 °C)
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Max. permissible relative humidity (operation)
    100 % (at 25 °C, non-condensing)
  • Nominal input voltage range
    96 V DC ... 110 V DC
  • Inrush current
    < 10 A (typical)
  • Type of protection
    Transient surge protection
  • Setting range of the output voltage (USet)
    18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
  • Selective Fuse Breaking (ISFB)
    60 A (12 ms)
  • Connection in series
    yes
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Peak switching voltages nominal load
    < 10 mVPP (20 MHz)
  • MTBF (IEC 61709, SN 29500)
    > 1357000 h (25 °C)
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section AWG min.
    24
  • Standard – Safety extra-low voltage
    EN 60950-1 (SELV)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Test field strength
    10 V/m (Test Level 3)
  • Surge voltage load (surge)
    EN 61000-4-5
  • I/O/S
    asymmetrical
  • ECLASS 11.0
    27210901
  • ECLASS 7.0
    27210901
  • UNSPSC 18.0
    39121041
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • ECLASS 10.0.1
    27210901
  • ECLASS 5.0
    27210900
  • UNSPSC 13.2
    39121041
  • ETIM 7.0
    EC002046
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Comments
    Criterion A
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 6.0
    27210900
  • UNSPSC 19.0
    39121041
  • Maximum power dissipation in no-load condition
    4 W (UIN 110 V DC)
  • Conductor cross section solid min.
    0.2 mm²
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Fast transients (burst)
    EN 61000-4-4
  • ECLASS 4.0
    27210900
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Discharge in air
    15 kV (Test Level 4)
  • Active current limitation
    18 A
  • Efficiency
    > 92 % (UIN 96 V DC / UOUT 24 V DC)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Stripping length
    7 mm
  • Electromagnetic HF field
    EN 61000-4-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo