2905010 Phoenix Contact DC/DC Converters
Part#:2905010
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (selective fuse breaking) technology, input: 96 - 110 V DC, output: 24 V DC/10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2905010 Phoenix Contact price in the box on the right side or send a quick quote.
2905010 Product Details
- Width 48 mm
- Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
- Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
- Nominal input voltage range 96 V DC ... 110 V DC
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 67.2 V DC ... 154 V DC
- Nominal output voltage 24 V DC ±1 %
- Depth with alternative assembly 51 mm
- Ambient temperature (start-up type tested) -40 °C
- Inrush current < 10 A (typical)
- Nominal output current (IN) 10 A (-40 °C ... 60 °C)
- Feedback voltage resistance 35 V DC
- Width with alternative assembly 122 mm
- Degree of protection IP20
- Degree of pollution 2
- Height 130 mm
- Height with alternative assembly 130 mm
- Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Current consumption 3.5 A (96 V DC)
- Type of protection Transient surge protection
- Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
- POWER BOOST (IBoost) 12.5 A (-40°C ... 40°C permanent, UOUT = 24 V DC )
- Active current limitation 18 A
- Power loss nominal load max. 22 W (UIN 110 V DC)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 2.5 mm²
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Depth 125 mm
- Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Mains buffering time typ. 10 ms (96 V DC)
- Protective circuit/component Varistor
- Derating 60 °C ... 70 °C (2.5%/K)
- Protection against overvoltage at the output (OVP) < 35 V DC
- Connection in series yes
- Maximum power dissipation in no-load condition 4 W (UIN 110 V DC)
- Protection class I
- Conductor cross section AWG min. 24
- Standard - Safe isolation DIN VDE 0100-410
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field EN 61000-4-3
- Fast transients (burst) EN 61000-4-4
- Surge voltage load (surge) EN 61000-4-5
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27210901
- ECLASS 5.1 27210900
- ECLASS 9.0 27210901
- UNSPSC 19.0 39121041
- Input fuse 10 A 150 V DC (internal (device protection))
- Selective Fuse Breaking (ISFB) 60 A (12 ms)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Residual ripple < 20 mVPP
- Insulation voltage input/output 1.5 kV (type test)
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 12
- EMC requirements for noise immunity EN 61000-6-1
- UL approvals UL/C-UL listed UL 508
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27210900
- ECLASS 4.1 27210900
- ECLASS 5.0 27210900
- ECLASS 7.0 27210901
- UNSPSC 18.0 39121041
- UNSPSC 13.2 39121041
- Connection in parallel Yes, for redundancy and increased capacity
- Max. capacitive load unlimited
- Net weight 0.9 kg
- MTBF (IEC 61709, SN 29500) > 1357000 h (25 °C)
- Conductor cross section solid max. 2.5 mm²
- Stripping length 7 mm
- EMC requirements for noise emission EN 61000-6-3
- Rail applications EN 50121-4
- Discharge in air 15 kV (Test Level 4)
- Frequency range 0.15 MHz ... 80 MHz
- Conducted interference EN 61000-4-6
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27210901
- ETIM 6.0 EC002046
- UNSPSC 21.0 39121041
- UNSPSC 20.0 39121041
- Peak switching voltages nominal load < 10 mVPP (20 MHz)
- Efficiency > 92 % (UIN 96 V DC / UOUT 24 V DC)
- Connection method Screw connection
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Screw thread M3
- Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
- Standard – Safety extra-low voltage EN 60950-1 (SELV)
- Contact discharge 8 kV (Test Level 4)
- Input 2 kV (Test Level 4 - symmetrical)
- I/O/S asymmetrical
- Voltage 10 V (Test Level 3)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 6.0 27210900
- ETIM 7.0 EC002046
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Test field strength 10 V/m (Test Level 3)
- Output 1 kV (Test Level 3 - symmetrical)
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2905010
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨