Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (selective fuse breaking) technology, input: 12 V DC, output: 12 V DC/8 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2905007 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 130 mm
- Height with alternative assembly 130 mm
- Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
- Depth with alternative assembly 35 mm
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Current consumption 12 A (12 V, IBOOST)
- Width 32 mm
- Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
- Ambient temperature (start-up type tested) -40 °C
- Input voltage range 9 V DC ... 18 V DC
- Protective circuit/component Varistor
- Selective Fuse Breaking (ISFB) 48 A (12 ms)
- Max. capacitive load unlimited
- Active current limitation 15 A
- MTBF (IEC 61709, SN 29500) > 1614000 h (25 °C)
- Width with alternative assembly 122 mm
- Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)
- Climatic class 3K3 (in acc. with EN 60721)
- Mains buffering time typ. 3 ms (12 V DC)
- Nominal output current (IN) 8 A (-25 °C ... 60 °C)
- Feedback voltage resistance 25 V DC
- Peak switching voltages nominal load < 10 mVPP (20 MHz)
- Insulation voltage input/output 1.5 kV (type test)
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section AWG min. 24
- Standard - Safe isolation DIN VDE 0100-410
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field EN 61000-4-3
- Output 1 kV (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 4.0 27210900
- ECLASS 5.1 27210900
- ETIM 6.0 EC002046
- Depth 125 mm
- Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Nominal input voltage range 12 V DC
- Type of protection Transient surge protection
- Nominal output voltage 12 V DC ±1 %
- POWER BOOST (IBoost) 10 A (-25 °C ... 40 °C permanent, UOUT = 12 V DC )
- Connection in series yes
- Power loss nominal load max. 11.8 W
- Connection method Screw connection
- Conductor cross section solid max. 2.5 mm²
- Stripping length 7 mm
- EMC requirements for noise emission EN 61000-6-3
- Contact discharge 8 kV (Test Level 4)
- Discharge in air 15 kV (Test Level 4)
- Surge voltage load (surge) EN 61000-4-5
- Voltage 10 V (Test Level 3)
- ECLASS 5.0 27210900
- UNSPSC 13.2 39121041
- UNSPSC 19.0 39121041
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Input fuse 25 A (internal (device protection))
- Setting range of the output voltage (USet) 5 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
- Connection in parallel Yes, for redundancy and increased capacity
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Net weight 0.8 kg
- Protection class III
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG max. 12
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Safety extra-low voltage EN 60950-1 (SELV)
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27210901
- ECLASS 9.0 27210901
- UNSPSC 21.0 39121041
- Inrush current < 6 A (typical)
- Derating 60 °C ... 70 °C (2.5%/K)
- Protection against overvoltage at the output (OVP) < 25 V DC
- Residual ripple < 20 mVPP
- Maximum power dissipation in no-load condition 1.5 W
- Efficiency > 89 %
- Conductor cross section flexible max. 2.5 mm²
- Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
- Rail applications EN 50121-4
- UL approvals UL/C-UL listed UL 508
- Frequency range 0.1 MHz ... 80 MHz
- Fast transients (burst) EN 61000-4-4
- I/O/S asymmetrical
- ECLASS 10.0.1 27210901
- ECLASS 4.1 27210900
- ETIM 7.0 EC002046
- UNSPSC 20.0 39121041
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible min. 0.2 mm²
- Screw thread M3
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Test field strength 10 V/m (Test Level 3)
- Input 1 kV (Test Level 1 - symmetrical)
- Conducted interference EN 61000-4-6
- REACh SVHC Lead 7439-92-1
- ECLASS 6.0 27210900
- ECLASS 7.0 27210901
- UNSPSC 18.0 39121041
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨