2902849 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2902849
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 73
Apr 24, 2024
About the product: Configurable temperature transducer for the connection of 2, 3, and 4-conductor resistance thermometers and resistance-type sensors. Can be configured via DIP switches or, with extended functionality, using the software. Screw connection, standard configu
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902849 Phoenix Contact price in the box on the right side or send a quick quote.
2902849 Product Details
- Temperature B
- EMC B
- ECLASS 10.0.1 27210129
- ETIM 3.0 EC001446
- Height 93.1 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Linear resistance measuring range 0 Ω ... 4000 Ω (Minimum measuring span: 10% of the selected measuring range)
- Connection technology 2-, 3-, 4-conductor
- Voltage output signal 0 V ... 10 V
- Max. output current 24.6 mA
- Load/output load voltage output 10 kΩ
- Power consumption ≤ 700 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω)
- Connection method Screw connection
- ECLASS 5.0 27200200
- ETIM 2.0 EC001446
- UNSPSC 6.01 30211506
- UNSPSC 7.0901 39121008
- UNSPSC 19.0 41112105
- Width 6.2 mm
- Depth 101.2 mm
- Maximum altitude ≤ 2000 m
- Configurable/programmable Yes
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors
- Number of outputs 1
- Max. output voltage approx. 12.3 V
- Ripple < 20 mVPP
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Stripping length 12 mm
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Maximum temperature coefficient 0.01 %/K
- Protective circuit Transient protection
- Degree of pollution 2
- Noise emission EN 61000-6-4
- Housing material PBT
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -20 °C ... 65 °C
- Degree of protection IP20
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Temperature measuring range -200 °C ... 850 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 850°C via DIP switches)
- Sensor input current approx. 200 µA
- Current output signal 0 mA ... 20 mA
- Load/output load current output 500 Ω (at 20 mA)
- Typical current consumption < 27 mA (at 24 V DC)
- Screw thread M3
- Transmission error resistance thermometer 0.1 % * 350 K / set measuring range; 0.1 % > 350 K (Pt/Ni)
- Conductor cross section AWG 26 ... 12
- Status display LED red
- Overvoltage category II
- Electromagnetic compatibility Conformance with EMC directive
- Mounting position any
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- Certificate DNV GL TAA00002R0
- Vibration B
- ECLASS 6.0 27200200
- ECLASS 5.1 27200200
- ETIM 6.0 EC002919
- UNSPSC 11 39121008
- UNSPSC 12.01 39121008
- UNSPSC 21.0 41112105
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Transmission error resistance-type sensor 2 Ω
- Electrical isolation Basic insulation according to EN 61010
- Rated insulation voltage 50 V AC/DC
- Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
- Color green
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- Typical deviation from the measuring range final value 0.02 %
- Standards/regulations EN 61000-4-6
- Humidity B
- Identification UL 508 Listed
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27200200
- ECLASS 4.1 27200200
- ECLASS 9.0 27210129
- ETIM 7.0 EC002919
- UNSPSC 13.2 41112105
- UNSPSC 20.0 41112105
- UNSPSC 18.0 41112105
- Designation Shipbuilding approval
- China RoHS Environmentally Friendly Use Period = 50 years
- ETIM 4.0 EC001446
- ECLASS 11.0 27210129
- ECLASS 7.0 27200206
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
This item can ship within 24h!
1-year warranty
$320.76
2902849
Stock:
73
Select Qty:
$320.76
$320.76 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?