2900582 Phoenix Contact Electrical Safety Devices

Phoenix Contact 2900582 Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
Phoenix Contact

Part#:2900582

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 4

04/19/2024

About the product: Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2900582 Phoenix Contact price in the box on the right side or send a quick quote.

2900582 Product Details

  • Height
    107 mm
  • Input name
    Control input right/left
  • Rated actuating voltage UC
    24 V DC
  • Switching threshold
    9.6 V (“0” signal)
  • Mains frequency
    50/60 Hz
  • Switching capacity according to IEC 60947-5-1
    3 A (230 V, AC15)
  • Motor starter type
    Reversing starter
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Status display
    Yellow LED
  • Connection method
    Screw connection
  • Torque
    0.5 Nm ... 0.6 Nm
  • Degree of pollution
    2
  • FLA
    0.6 A (500 V AC)
  • ECLASS 10.0.1
    27370905
  • ECLASS 5.0
    27024000
  • ETIM 2.0
    EC001037
  • UNSPSC 7.0901
    39121514
  • Depth
    114 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Typical turn-off time
    < 30 ms
  • Rated operating current Ie
    0.6 A (AC-51)
  • Note
    Confirmation: floating change-over contact, signal contact
  • Contact type
    1 changeover contact
  • Maximum power dissipation
    1.5 W
  • Operating mode
    100% operating factor
  • Screw thread
    M3
  • Rated surge voltage
    6 kV
  • Certificate
    NLDX.E228652
  • SCCR
    100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27021100
  • ETIM 6.0
    EC001037
  • UNSPSC 6.01
    30211915
  • UNSPSC 19.0
    25173902
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Rated control supply current IS
    40 mA
  • Rated actuating current IC
    5 mA (Input type 1)
  • Output name
    Acknowledge output
  • Rated operating voltage Ue
    500 V AC
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10A
  • Leakage current
    0 mA
  • Mounting type
    DIN rail mounting
  • Stripping length
    8 mm
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Rated insulation voltage
    500 V
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • Category code
    NLDX
  • Group installation
    20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
  • ECLASS 4.1
    27021100
  • ECLASS 7.0
    27024002
  • UNSPSC 12.01
    39121514
  • UNSPSC 21.0
    25173902
  • Ambient temperature (operation)
    -25 °C ... 70 °C (observe derating)
  • Degree of protection
    IP20
  • Minimum power dissipation
    1.1 W
  • Connection name
    Load circuit
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Conductor cross section AWG
    24 ... 14
  • Standards/regulations
    IEC 60947-1
  • Identification
    ≤ 3
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27024000
  • ECLASS 6.0
    27024000
  • ETIM 7.0
    EC001037
  • UNSPSC 13.2
    25173902
  • Width
    22.5 mm
  • Maximum altitude
    ≤ 2000 m
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Type of protection
    Surge protection
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Operating voltage range
    42 V AC ... 550 V AC
  • Load current range
    75 mA ... 600 mA (see to derating)
  • Cooling time
    20 min. (for auto reset)
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Assembly instructions
    alignable, for spacing see derating
  • Operating voltage display
    Green LED
  • Indication
    Red LED
  • Overvoltage category
    III
  • Designation
    Category (ISO 13849)
  • Additional text
    Safe shutdown
  • ECLASS 11.0
    27370905
  • ECLASS 9.0
    27370905
  • ETIM 4.0
    EC001037
  • ETIM 3.0
    EC001037
  • UNSPSC 18.0
    25173902
  • UNSPSC 20.0
    25173902
  • UNSPSC 11
    39121514

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 3 days!

1-year warranty

$360.05

2900582

Stock:

4

Select Qty:

$360.05

$360.05 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo