2900566 Phoenix Contact Electrical Safety Devices

Phoenix Contact 2900566 Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.
Phoenix Contact

Part#:2900566

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 3

May 1, 2024

About the product: Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2900566 Phoenix Contact price in the box on the right side or send a quick quote.

2900566 Product Details

  • Maximum altitude
    ≤ 2000 m
  • Input name
    Control input
  • Switching threshold
    9.6 V (“0” signal)
  • Height
    107 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Rated actuating voltage UC
    24 V DC
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Status display
    Yellow LED
  • Load current range
    75 mA ... 600 mA (see to derating)
  • Note
    Confirmation: floating change-over contact, signal contact
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Maximum power dissipation
    1.5 W
  • Indication
    Red LED
  • Screw thread
    M3
  • Standards/regulations
    IEC 60947-1
  • SCCR
    100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • FLA
    0.6 A (500 V AC)
  • ECLASS 4.0
    27021100
  • ETIM 3.0
    EC001037
  • ETIM 4.0
    EC001037
  • UNSPSC 12.01
    39121514
  • UNSPSC 21.0
    25173902
  • Ambient temperature (operation)
    -25 °C ... 70 °C (observe derating)
  • Depth
    114 mm
  • Rated control supply current IS
    40 mA
  • Typical turn-off time
    < 30 ms
  • Rated operating current Ie
    0.6 A (AC-51)
  • Leakage current
    0 mA
  • Switching capacity according to IEC 60947-5-1
    3 A (230 V, AC15)
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Assembly instructions
    alignable, for spacing see derating
  • Stripping length
    8 mm
  • Rated surge voltage
    6 kV
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • Group installation
    20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
  • Category code
    NLDX
  • ECLASS 10.0.1
    27370905
  • ECLASS 5.1
    27024000
  • ETIM 6.0
    EC001037
  • UNSPSC 7.0901
    39121514
  • Width
    22.5 mm
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Type of protection
    Surge protection
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Rated operating voltage Ue
    500 V AC
  • Cooling time
    20 min. (for auto reset)
  • Operating mode
    100% operating factor
  • Connection name
    Load circuit
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Torque
    0.5 Nm ... 0.6 Nm
  • Degree of pollution
    2
  • Designation
    Category (ISO 13849)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27024000
  • ECLASS 9.0
    27370905
  • ETIM 7.0
    EC001037
  • UNSPSC 18.0
    25173902
  • UNSPSC 19.0
    25173902
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Degree of protection
    IP20
  • Rated actuating current IC
    5 mA (Input type 1)
  • Operating voltage range
    42 V AC ... 550 V AC
  • Mains frequency
    50/60 Hz
  • Contact type
    1 changeover contact
  • Operating voltage display
    Green LED
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Rated insulation voltage
    500 V
  • Identification
    ≤ 3
  • Certificate
    NLDX.E228652
  • ECLASS 11.0
    27370905
  • ECLASS 7.0
    27024002
  • ETIM 2.0
    EC001037
  • UNSPSC 11
    39121514
  • UNSPSC 20.0
    25173902
  • Output name
    Acknowledge output
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10A
  • Motor starter type
    Direct starter
  • Mounting type
    DIN rail mounting
  • Minimum power dissipation
    1.1 W
  • Connection method
    Screw connection
  • Conductor cross section AWG
    24 ... 14
  • Overvoltage category
    III
  • Additional text
    Safe shutdown
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27021100
  • ECLASS 6.0
    27024000
  • UNSPSC 6.01
    30211915
  • UNSPSC 13.2
    25173902

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$239.14

2900566

Stock:

3

Select Qty:

$239.14

$239.14 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo