Phoenix Contact 2838597 LSA-PLUS plug with protection for conductor pairs in floating signal circuits. Nominal voltage: 12 V DC
Phoenix Contact

Part#:2838597

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: LSA-PLUS plug with protection for conductor pairs in floating signal circuits. Nominal voltage: 12 V DC

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2838597 Phoenix Contact price in the box on the right side or send a quick quote.

2838597 Product Details

  • Width
    9.5 mm
  • Depth
    53.5 mm
  • Degree of pollution
    2
  • Type
    LSA-PLUS module
  • Rated current
    380 mA AC (25 °C)
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Output voltage limitation at 1 kV/µs (line-earth) spike
    ≤ 700 V
  • Degree of protection
    IP20
  • Flammability rating according to UL 94
    V-0
  • Mounting type
    On CT-TERMIBLOCK and LSA-PLUS disconnect strip
  • Direction of action
    Line-Line & Line-Earth Ground
  • Maximum continuous voltage UC
    ± 15 V DC
  • Max. discharge current Imax (8/20) µs maximum (line-earth)
    10 kA (in total)
  • Residual voltage with Ian (10/1000) µs (line-line)
    ≤ 25 V
  • Voltage protection level Up static (line-earth)
    ≤ 45 V (C2 - 10 kV / 5 kA)
  • Input attenuation aE, sym.
    0.3 dB (≤ 400 kHz)
  • Resistance per path
    3.3 Ω 10 %
  • Impulse durability (line-earth)
    C2 - 4 kV / 2 kA
  • Alternating current carrying capacity (line-earth)
    5 A - 1 s
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 6.0
    27130800
  • ETIM 4.0
    EC000943
  • ETIM 7.0
    EC000943
  • UNSPSC 20.0
    39121620
  • Ambient temperature (operation)
    -25 °C ... 75 °C
  • Standards for cearances and creepage distances
    DIN VDE 0110-1
  • Number of positions
    2
  • IEC test classification
    B2
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Nominal pulse current Ian (10/1000) µs (line-line)
    100 A
  • Output voltage limitation at 1 kV/µs (line-line) static
    ≤ 25 V
  • Residual voltage with Ian (10/1000) µs (line-earth)
    ≤ 25 V
  • Voltage protection level Up static (line-line)
    ≤ 25 V (C2 - 10 kV / 5 kA)
  • Surge protection fault message
    none
  • Connection method IN
    COMTRAB plug-in system
  • Standards/regulations
    IEC 61643-21
  • ECLASS 5.0
    27130800
  • ETIM 2.0
    EC000943
  • UNSPSC 11
    39121610
  • Height
    21 mm
  • Color
    black
  • Arrester can be tested with CHECKMASTER from software version:
    From SW rev. 1.10
  • VDE requirement class
    B2
  • Residual current IPE
    ≤ 2 µA
  • Total discharge current Itotal (10/350) µs
    2.5 kA
  • Nominal pulse current Ian (10/1000) µs (line-earth)
    100 A
  • Output voltage limitation at 1 kV/µs (line-earth) static
    ≤ 700 V
  • Voltage protection level Up (line-earth)
    ≤ 700 V (C2 - 10 kV / 5 kA)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Connection method
    Spring contact
  • ECLASS 11.0
    27130807
  • ECLASS 4.1
    27130800
  • ECLASS 7.0
    27130807
  • UNSPSC 6.01
    30212010
  • UNSPSC 19.0
    39121620
  • Housing material
    PA
  • Overvoltage category
    II
  • Nominal voltage UN
    12 V DC
  • Operating effective current IC at UC
    ≤ 5 µA
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    1 kA
  • Residual voltage at In (line-line)
    ≤ 22 V
  • Voltage protection level Up (line-line)
    ≤ 40 V (C2 - 10 kV / 5 kA)
  • Residual voltage at In (line-earth)
    ≤ 45 V
  • Capacity (line-line)
    1.5 nF (f=1 MHz / VR= 0 V)
  • Connection method OUT
    COMTRAB plug-in system
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.1
    27130800
  • ETIM 3.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 12.01
    39121610
  • UNSPSC 18.0
    39121620
  • Output voltage limitation at 1 kV/µs (line-line) spike
    ≤ 45 V
  • Response time tA (line-line)
    ≤ 1 ns
  • Cut-off frequency fg (3 dB), sym. in 100 Ω system
    1.2 MHz
  • Impulse durability (line-line)
    C2 - 4 kV / 2 kA
  • Connection technology
    LSA-PLUS
  • Standards/specifications
    IEC 61643-21 2000
  • ECLASS 4.0
    27130800
  • ECLASS 9.0
    27130807
  • ETIM 6.0
    EC000943
  • UNSPSC 13.2
    39121620
  • UNSPSC 21.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2838597

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo