2838568 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2838568 LSA-PLUS plug (COMTRAB CTM) with protection for conductor pairs in floating signal circuits. Nominal voltage: 60 V DC
Phoenix Contact

Part#:2838568

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: LSA-PLUS plug (COMTRAB CTM) with protection for conductor pairs in floating signal circuits. Nominal voltage: 60 V DC

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2838568 Phoenix Contact price in the box on the right side or send a quick quote.

2838568 Product Details

  • Depth
    52.4 mm
  • Degree of pollution
    2
  • Direction of action
    Line-Line & Line-Earth Ground
  • Rated current
    380 mA AC (25 °C)
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Residual voltage at In (line-line)
    ≤ 95 V
  • Residual voltage with Ian (10/1000) µs (line-line)
    ≤ 35 V
  • Response time tA (line-line)
    ≤ 1 ns
  • Voltage protection level Up static (line-earth)
    ≤ 90 V (C2 - 10 kV / 5 kA)
  • Capacity (line-line)
    typ. 1.2 nF
  • Connection method OUT
    COMTRAB plug-in system
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.0
    27130800
  • ETIM 6.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • Altitude
    ≤ 2000 m (amsl (above mean sea level))
  • Flammability rating according to UL 94
    V-0
  • Arrester can be tested with CHECKMASTER from software version:
    From SW rev. 1.10
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Total discharge current Itotal (10/350) µs
    2.5 kA
  • Output voltage limitation at 1 kV/µs (line-earth) static
    ≤ 700 V
  • Residual voltage at In (line-earth)
    ≤ 60 V
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 500 kHz / 100 Ω)
  • Alternating current carrying capacity (line-earth)
    5 A - 1 s
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27130800
  • ECLASS 6.0
    27130800
  • ETIM 3.0
    EC000943
  • UNSPSC 13.2
    39121620
  • UNSPSC 21.0
    39121620
  • Width
    9.4 mm
  • Housing material
    PA 6.6
  • Overvoltage category
    II
  • Maximum continuous voltage UC
    60 V DC
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Nominal pulse current Ian (10/1000) µs (line-line)
    100 A
  • Output voltage limitation at 1 kV/µs (line-earth) spike
    ≤ 700 V
  • Voltage protection level Up (line-earth)
    ≤ 700 V (C2 - 10 kV / 5 kA)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Impulse durability (line-line)
    B2 - 4 kV / 100 A
  • Impulse durability (line-earth)
    B2 - 4 kV / 100 A
  • ECLASS 5.1
    27130800
  • ECLASS 7.0
    27130807
  • UNSPSC 6.01
    30212010
  • UNSPSC 11
    39121610
  • UNSPSC 12.01
    39121610
  • Height
    21 mm
  • Degree of protection
    IP20
  • Mounting type
    On CT-TERMIBLOCK and LSA-PLUS disconnect strip
  • IEC test classification
    B2
  • Operating effective current IC at UC
    ≤ 70 µA
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    1 kA
  • Nominal pulse current Ian (10/1000) µs (line-earth)
    100 A
  • Voltage protection level Up (line-line)
    ≤ 200 V (C2 - 10 kV / 5 kA)
  • Cut-off frequency fg (3 dB), sym. in 100 Ω system
    typ. 2 MHz
  • Surge protection fault message
    none
  • Connection method IN
    COMTRAB plug-in system
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • ECLASS 4.1
    27130800
  • ECLASS 9.0
    27130807
  • ETIM 7.0
    EC000943
  • UNSPSC 20.0
    39121620
  • UNSPSC 18.0
    39121620
  • Ambient temperature (operation)
    -25 °C ... 75 °C
  • Color
    jet black RAL 9005
  • Type
    LSA-PLUS module
  • Nominal voltage UN
    60 V DC
  • Residual current IPE
    ≤ 2 µA
  • Output voltage limitation at 1 kV/µs (line-line) spike
    ≤ 160 V
  • Residual voltage with Ian (10/1000) µs (line-earth)
    ≤ 12 V
  • Voltage protection level Up static (line-line)
    ≤ 95 V (C2 - 10 kV / 5 kA)
  • Resistance per path
    3.3 Ω 20 %
  • Connection method
    Spring contact
  • Connection technology
    LSA-PLUS
  • ECLASS 11.0
    27130807
  • ETIM 2.0
    EC000943
  • ETIM 4.0
    EC000943
  • UNSPSC 19.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2838568

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo