2801263 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2801263 Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for two 2-wire floating signal circuits.
Phoenix Contact

Part#:2801263

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for two 2-wire floating signal circuits.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2801263 Phoenix Contact price in the box on the right side or send a quick quote.

2801263 Product Details

  • Height
    109.3 mm
  • Color
    jet black RAL 9005
  • Rated current
    700 mA (50 °C)
  • Operating effective current IC at UC
    ≤ 1 mA (in the signal circuit)
  • Voltage protection level Up static (line-line)
    ≤ 65 V (C1 - 1 kV/500 A)
  • Resistance per path
    1.2 Ω ±5 %
  • Pulse reset time (line-line)
    ≤ 4000 ms
  • Standards/specifications
    IEC 61643-21 2000 + A1:2008 + A2:2012
  • ECLASS 4.0
    27130800
  • ECLASS 9.0
    27130807
  • UNSPSC 7.0901
    39121610
  • UNSPSC 13.2
    39121620
  • Horizontal pitch
    1 Div.
  • Degree of protection
    IP20
  • Flammability rating according to UL 94
    V-0
  • Nominal discharge current In (8/20) µs (line-earth)
    10 kA
  • Nominal discharge current In (8/20) µs (line-line)
    10 kA
  • Voltage protection level Up (line-earth)
    ≤ 600 V (C1 - 1 kV/500 A)
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 1.1 MHz
  • Surge protection fault message
    Optical, multi-stage
  • Stripping length
    10 mm
  • ECLASS 11.0
    27130807
  • ECLASS 6.0
    27130800
  • ETIM 6.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 11
    39121610
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Type
    DIN rail module, two-section, divisible
  • IEC test classification
    C1
  • Maximum continuous voltage UC
    30 V DC
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    2.5 kA
  • Response time tA (line-line)
    ≤ 1 ns
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 270 kHz/150 Ω)
  • Capacity (line-line)
    typ. 2 nF
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-earth)
    ≤ 2600 ms
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27130800
  • ETIM 3.0
    EC000943
  • ETIM 4.0
    EC000943
  • UNSPSC 18.0
    39121620
  • Depth
    77.5 mm (incl. DIN rail 7.5 mm)
  • Width
    17.7 mm
  • Housing material
    PA 6.6
  • Mounting type
    DIN rail: 35 mm
  • Nominal voltage UN
    24 V DC
  • Total discharge current Itotal (8/20) µs
    20 kA
  • Response time tA (line-earth)
    ≤ 100 ns
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Connection method
    DIN rail NS35
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27130800
  • ECLASS 7.0
    27130807
  • UNSPSC 12.01
    39121610
  • UNSPSC 21.0
    39121620
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Note
    Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Residual current IPE
    ≤ 2 µA (per signal circuit)
  • Voltage protection level Up (line-line)
    ≤ 80 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-earth)
    ≤ 60 V (C2 - 10 kV / 5 kA)
  • Max. required back-up fuse
    800 mA (FF)
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.0
    27130800
  • ETIM 7.0
    EC000943
  • UNSPSC 20.0
    39121620
  • UNSPSC 19.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2801263

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo