Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2800977 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2800977 Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for one 2-wire floating signal circuit. Indirect grounding via gas-filled surge arrester.
Phoenix Contact

Part#:2800977

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for one 2-wire floating signal circuit. Indirect grounding via gas-filled surge arrester.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2800977 Phoenix Contact price in the box on the right side or send a quick quote.

2800977 Product Details

  • Horizontal pitch
    1 Div.
  • Permissible humidity (operation)
    5 % ... 95 %
  • Color
    jet black RAL 9005
  • Rated current
    1000 mA (40 °C)
  • Height
    91.1 mm
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Mounting type
    DIN rail: 35 mm
  • Note
    Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
  • Nominal discharge current In (8/20) µs (line-earth)
    10 kA
  • Total discharge current Itotal (8/20) µs
    20 kA
  • Voltage protection level Up static (line-line)
    ≤ 65 V (C1 - 1 kV/500 A)
  • Surge protection fault message
    Optical, multi-stage
  • Depth
    77.5 mm (incl. DIN rail 7.5 mm)
  • Degree of protection
    IP20
  • Type
    DIN rail module, two-section, divisible
  • IEC test classification
    C1
  • Residual current IPE
    ≤ 1 µA
  • Voltage protection level Up (line-line)
    ≤ 80 V (C1 - 1 kV/500 A)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Response time tA (line-signalground)
    ≤ 100 ns
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Screw thread
    M3
  • Connection method
    DIN rail NS35
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27130807
  • ECLASS 6.0
    27130800
  • ETIM 4.0
    EC000943
  • ETIM 6.0
    EC000943
  • UNSPSC 12.01
    39121610
  • Width
    17.7 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Operating effective current IC at UC
    ≤ 1 mA (in the signal circuit)
  • Maximum continuous voltage UC
    30 V DC
  • Response time tA (line-line)
    ≤ 1 ns
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 270 kHz/150 Ω)
  • Max. required back-up fuse
    1 A (FF)
  • Pulse reset time (line-earth)
    ≤ 30 ms
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Standards/specifications
    IEC 61643-21 2000 + A1:2008, modified
  • ECLASS 4.0
    27130800
  • ECLASS 7.0
    27130807
  • ETIM 7.0
    EC000943
  • UNSPSC 11
    39121610
  • UNSPSC 19.0
    39121620
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Flammability rating according to UL 94
    V-0
  • Housing material
    PA 6.6
  • Nominal voltage UN
    24 V DC
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    2.5 kA
  • Voltage protection level Up (line-signalground)
    ≤ 600 V (C1 - 1 kV/500 A)
  • Capacity (line-earth)
    typ. 2 nF
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-signalground)
    ≤ 2600 ms
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 5.1
    27130800
  • ECLASS 9.0
    27130807
  • UNSPSC 6.01
    30212010
  • UNSPSC 21.0
    39121620
  • Nominal discharge current In (8/20) µs (line-line)
    10 kA
  • Voltage protection level Up (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 1.1 MHz
  • Resistance per path
    1.2 Ω ±5 %
  • Pulse reset time (line-line)
    ≤ 4000 ms
  • Stripping length
    8 mm
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.0
    27130800
  • UNSPSC 7.0901
    39121610
  • UNSPSC 18.0
    39121620
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Tightening torque
    0.5 Nm
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27130800
  • ETIM 3.0
    EC000943
  • UNSPSC 13.2
    39121620
  • UNSPSC 20.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2800977

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo