2702464 Phoenix Contact Programmable Logic Controllers
Part#:2702464
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 13
Apr 24, 2024
About the product: Axioline F XC, Temperature recording module, Analog inputs: 8 (8 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V), connection method: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, Extreme condit
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702464 Phoenix Contact price in the box on the right side or send a quick quote.
2702464 Product Details
- Height 126.1 mm
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Degree of protection IP20
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section AWG min. 24
- Conductor cross section AWG max. 16
- ETIM 4.0 EC001596
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- IECEx Ex ec IIC T4 Gc
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ECLASS 10.0.1 27242601
- ECLASS 5.1 27242601
- ETIM 3.0 EC001599
- UNSPSC 6.01 43172015
- UNSPSC 21.0 32151602
- Designation Supply for analog modules (UA)
- Conductor cross section solid max. 1.5 mm²
- Color traffic grey A RAL 7042
- Stripping length 8 mm
- Mounting type DIN rail
- Current consumption typ. 45.3 mA
- Power consumption typ. 1.63 W (entire device)
- Supply voltage 24 V DC
- Width 53.6 mm
- Ambient temperature (operation) -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Connection method Push-in connection
- Measuring principle Sigma/Delta process
- Connection technology 2-conductor (shielded, twisted pair)
- Input filter time 40 ms
- ECLASS 7.0 27242601
- UNSPSC 13.2 32151602
- UNSPSC 11 39121311
- Depth 54 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Conductor cross section flexible min. 0.2 mm²
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Net weight 144 g
- Note on weight specifications with connectors and bus base module
- Number of interfaces 2
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Number of inputs 8 +1 mm (8 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V)
- Description of the input Inputs for thermocouples or linear voltage
- Sensor types that can be used (TC) U, T, L, J, E, K, N, S, R, B, C, W, HK
- ECLASS 9.0 27242601
- ETIM 6.0 EC001596
- UNSPSC 12.01 39121311
- UNSPSC 20.0 32151602
- Mounting position any (no temperature derating; Parameterize the mounting position using the object 0080hex ParaTable!)
- Transmission speed 100 Mbps
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Protective circuit Surge protection electronic (35 V, 0.5 s)
- Input name Analog inputs
- Sensor types (RTD) that can be used Pt 100 (4 external cold junctions, can also be used as a sensor input)
- Measured value representation 16 bits (15 bits + sign bit)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
- ATEX II 3 G Ex ec IIC T4 Gc
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 4.0 27240405
- ECLASS 5.0 27242201
- ETIM 7.0 EC001596
- UNSPSC 18.0 32151602
- UNSPSC 7.0901 43201404
- UNSPSC 19.0 32151602
- REACh SVHC Lead 7439-92-1
- ECLASS 6.0 27242600
- Type of protection Short-circuit protection, overload protection of the inputs
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- ECLASS 11.0 27242601
- UL, USA/Canada cULus
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.1 27240405
- A/D converter resolution 24 bit
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A for shielded cables, 2 kV
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
This item can ship within 24h!
1-year warranty
$809.37
2702464
Stock:
13
Select Qty:
$809.37
$809.37 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨