2701508 Phoenix Contact Programmable Logic Controllers
Part#:2701508
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Axioline E PROFIBUS device in a metal housing with 8 IO-Link ports and 4 digital inputs, 24 V DC, M12 fast connection technology
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701508 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- UNSPSC 7.0901 43201404
- UNSPSC 13.2 32151602
- Width 60 mm
- Drill hole spacing 198.5 mm
- Number of ports 4
- Output description IO-Link ports in digital output (DO) mode
- Nominal load, inductive 3.6 VA (0.8 H, 160 Ω, at nominal load)
- Behavior with overload Shutdown with automatic restart
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.0 27240400
- ECLASS 6.0 27242600
- ETIM 2.0 EC001433
- Permissible humidity (storage/transport) 5 % ... 95 %
- Nominal output voltage 24 V DC
- Nominal load, ohmic 3.6 W (160 Ω, at nominal load)
- Output current when switched off max. 300 µA
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Ambient temperature (operation) -25 °C ... 60 °C
- Housing material Zinc die-cast
- Number 2
- Transmission physics PROFIBUS-DP-compliant copper cable
- Equipment type PROFIBUS slave
- Supply voltage 24 V DC
- Input name Digital inputs at pin 2 for type A ports
- Nominal input current at UIN typ. 3 mA
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Input frequency 0.5 kHz
- Switching rate 1 per second, maximum (at nominal inductive load)
- Depth 38 mm
- Output voltage when switched off max. 1 V
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Permissible humidity (operation) 5 % ... 95 %
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Connection method M12 connector, X01 ... X04 have double occupancy
- Connection technology 3-conductor
- Number of inputs max. 8 (EN 61131-2 type 1)
- Sensor current per channel max. 200 mA (from L+/L-)
- Total sensor current max. 1.6 A (from L+/L-)
- Number of outputs max. 8
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27242604
- ECLASS 5.1 27242600
- Signal delay max. 150 µs (when switched on)
- Test section 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection 500 V AC 50 Hz 1 min.
- Degree of protection IP65/IP67
- Net weight 710 g
- Transmission speed 9.6 kbps ... 12 Mbps (Automatic baud rate detection)
- Height 185 mm
- Number of positions 4
- Nominal input voltage UIN 24 V DC
- Input filter time < 1000 µs
- Input voltage range "0" signal -0.3 V DC ... 5 V DC
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- Port type Class A
- Maximum output current per channel 150 mA
- ECLASS 4.1 27240400
- ECLASS 7.0 27242604
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Designation IO-Link
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 10.0.1 27242604
- Designation connection point Copper cable
- System-specific protocols PROFIBUS protocols DP V1
- Protective circuit Overload protection, short-circuit protection of sensor supply
- Cycle Time min. 2 ms (MasterCycleTime: PDInput* + PDOutput* + OnReqData* < = 17 Bytes, COM3; * see "IO-Link Interface and System Specification V1.1.2")
- Maximum output current per device 1.2 A
- Limitation of the voltage induced on circuit interruption -15 V DC
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ECLASS 5.0 27242200
- ETIM 3.0 EC001599
- ETIM 7.0 EC001599
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Current consumption typ. 30 mA ±15 % (at 24 V DC)
- Permissible cable length < 20 m
- Note on the connection method B-coded
- Nominal voltage for I/O supply 24 V DC
- Description of the input IO-Link ports in digital input (DI) mode
- Address area assignment 1 ... 126, adjustable
- Nominal current for every IO-Link port max. 150 mA (at C/Q (pin 4), maximum of 1.6 A over all 8 IO-Link C/Q and L+ cables)
- Type of protection Overload protection
- Input voltage range "1" signal 15 V DC ... 30 V DC
- ECLASS 9.0 27242604
- ETIM 6.0 EC001599
- UNSPSC 18.0 32151602
- ETIM 4.0 EC001599
- UNSPSC 21.0 32151602
- Nominal input current typ. 3 mA
- UNSPSC 12.01 39121311
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- UNSPSC 19.0 32151602
- UNSPSC 11 39121311
- UNSPSC 6.01 43172015
- UNSPSC 20.0 32151602
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨