About the product: Axioline F, Analog input module, Analog inputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, connection method: 2-, 3-, 4-conductor, transmission speed in the local bus: 100 Mbps, integrated sensor supply, degree of protection: IP20, includ
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 2688501 Phoenix Contact price in the box on the right side or send a quick quote.
2688501 Product Details
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section flexible max. 1.5 mm²
- Number 2
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Connection method Push-in connection
- Designation Supply for analog modules (UA)
- Conductor cross section solid max. 1.5 mm²
- Color traffic grey A RAL 7042
- Transmission speed 100 Mbps
- Current consumption max. 45 mA (IiS = 0 mA)
- Connection technology 2-, 3-, 4-conductor
- Data formats IB IL, S7-compatible
- Common mode voltage range signal - ground -50 V DC ... 50 V DC
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 10.0.1 27242601
- ECLASS 5.0 27242200
- ETIM 4.0 EC001599
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Net weight 191 g
- Conductor cross section AWG max. 16
- Mounting position any (no temperature derating)
- Power consumption max. 5.88 W (Full load)
- Input name Analog inputs
- Limit frequency (3 dB) 30 Hz
- Voltage input signal 0 V ... 5 V
- ECLASS 4.0 27240400
- ECLASS 6.0 27242600
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ETIM 3.0 EC001599
- UNSPSC 11 39121311
- Stripping length 8 mm
- Description of the input Differential inputs, voltage
- Note regarding the connection technology shielded, twisted pair
- Type of protection Transient protection of inputs
- Input resistance of voltage input 268 kΩ (typical)
- Input filter 30 Hz, 12 kHz and mean-value generation (can be parameterized)
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27242600
- ECLASS 9.0 27242601
- UNSPSC 7.0901 43201404
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section solid min. 0.2 mm²
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Supply voltage 24 V DC (I/O supply and sensor supply)
- Protective circuit Surge protection electronic (35 V, 0.5 s)
- A/D conversion time 31.25 µs
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 up to HW 02: Criterion B,DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
- Number of inputs 4
- Measured value representation 16 bits (15 bits + sign bit)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.1 27240400
- ETIM 6.0 EC001596
- UNSPSC 12.01 39121311
- UNSPSC 21.0 32151602
- Depth 54 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Height 126.1 mm
- ECLASS 7.0 27242601
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section AWG min. 24
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 11.0 27242601
- Width 35 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Note on weight specifications with connectors and bus base module
- A/D converter resolution 16 bit
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- UNSPSC 6.01 43172015
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Mounting type DIN rail
- UNSPSC 18.0 32151602
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- ETIM 7.0 EC001596
- UNSPSC 19.0 32151602
- UNSPSC 20.0 32151602
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- UNSPSC 13.2 32151602
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨