1135749 Phoenix Contact Electrical Circuit Protection & Load Centers

Phoenix Contact 1135749 Single-channel, electronic fuse for the protection of 24 V loads. 24VDC, 2 Amp.  Simple potential distribution using terminal blocks from the CLIPLINE complete system. With status output, reset input, and electronic interlock. For installation on DIN rail
Phoenix Contact

Part#:1135749

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Single-channel, electronic fuse for the protection of 24 V loads. 24VDC, 2 Amp. Simple potential distribution using terminal blocks from the CLIPLINE complete system. With status output, reset input, and electronic interlock. For installation on DIN rail

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 1135749 Phoenix Contact price in the box on the right side or send a quick quote.

1135749 Product Details

  • Ambient temperature (storage/transport)
    -40 °C ... 70 °C
  • Vibration (operation)
    10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
  • Degree of pollution
    2
  • Rated current IN
    24 A DC (Total current input)
  • Efficiency
    > 99 %
  • Temperature derating
    21 A (Total current at 60°C)
  • MTBF (IEC 61709, SN 29500)
    28571428 h (at 25 °C with 21 % load)
  • Ambient temperature (operation)
    -30 °C ... 60 °C
  • Color
    traffic grey A RAL 7042
  • Protection class
    III
  • Fuse type
    electronic
  • Rated voltage
    24 V DC
  • Waiting time after switch off of a channel
    5 s (at overload / short circuit)
  • Short-circuit switching capacity
    300 A
  • Overvoltage switch-off shutdown load circuit
    ≥ 30.5 V DC (active)
  • Conductor cross section, flexible, with ferrule, with plastic sleeve
    0.2 mm² ... 2.5 mm²
  • Pulse length reset input
    ≥ 50 ms (High)
  • Channel LED yellow
    lit (Channel switched on, channel load > 80% )
  • Temperature
    D
  • Vibration
    B
  • Width
    6.2 mm
  • Altitude
    ≤ 3000 m up to 52 °C (amsl (above mean sea level))
  • Mounting type
    DIN rail: 35 mm
  • Number of positions
    1
  • Rated surge voltage
    0.5 kV
  • Fail-safe element
    5 A DC
  • Height
    105.8 mm
  • Humidity test
    96 h, 95 % RH, 40 °C
  • Flammability rating according to UL 94
    V-0
  • Degree of protection
    IP20
  • Measuring tolerance I
    ± 15 %
  • Closed circuit current I0
    typ. 8 mA
  • Power dissipation
    typ. 0.15 W (No-load operation)
  • Dielectric strength
    max. 35 V DC (Load circuit)
  • Max. capacitive load load circuit
    20000 µF (Depending on the current setting and the short-circuit current available)
  • Output voltage status output
    24 V DC (Error)
  • Conductor cross section AWG
    24 ... 12
  • Voltage reset input
    < 5 V DC (Low state)
  • Connection name
    Main circuit OUT
  • Identification
    DNV GL
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 9.0
    27141116
  • Depth
    55.6 mm (incl. DIN rail 7.5 mm)
  • Shock (operation)
    30g (IEC 60068-2-27, Test Ea)
  • Type
    DIN rail module, one-piece
  • Operating voltage
    18 V DC ... 30 V DC
  • Feedback resistance
    max. 35 V DC
  • Tripping method
    E (electronic)
  • Shutdown time load circuit
    ≤ 10 ms (for short circuit > 2.0 x IN)
  • Stripping length
    8 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve
    0.2 mm² ... 2.5 mm²
  • Channel LED off
    off (Channel switched off)
  • Channel LED red
    lit (Channel switched off, over- or undervoltage active)
  • Standards/specifications
    EN 61000-6-2 EMC – Immunity for industrial areas
  • EMC
    B
  • ECLASS 11.0
    27140401
  • Module initialization time
    1 s
  • Required backup fuse
    Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element.
  • Voltage drop
    0.07 V (at 2 A)
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • Input voltage reset input
    7 V DC ... 30 V DC (Reset with falling edge)
  • Designation
    Shipbuilding approval
  • Humidity
    B
  • Enclosure
    A
  • Undervoltage switch-off load circuit
    ≤ 17.8 V DC (active)
  • Output current status output
    max. 0.015 A (Short-circuit-proof)
  • Current consumption reset input
    typ. 0.4 mA (at 24 V DC)
  • Channel LED green
    lit (Channel switched on)
  • Connection method
    Push-in connection
  • ECLASS 10.0.1
    27140401

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty