1104972 Phoenix Contact Electrical Safety Devices
Part#:1104972
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 12
Nov 21, 2024
Configurable safety module (basic module), 8 safe inputs, 2 safe outputs, 2 reset inputs, 2 signal outputs, 4 clock outputs, can be extended via TBUS, up to SILCL 3, Cat. 4/PL e, SIL 3, plug-in Push-in terminal block, TBUS connector not included
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1104972 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 113.6 mm
- Max. permissible humidity (storage/transport) 95 % (non-condensing)
- Rated control circuit supply voltage US 24 V DC -20 % / +20 % (external fuse, typically 4 A)
- Inrush current max. 750 mA (Δt 1 s)
- Number of inputs 2
- Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US)
- Leakage current max. 100 µA
- Short-circuit protection Yes (self-limitation at 1.1 A)
- Output voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Width 22.61 mm
- Max. permissible relative humidity (operation) 95 % (non-condensing)
- Power consumption at US typ. 1.32 W (Outputs inactive)
- Filter time 250 ms ±2 ms (Test pulse rate > 500 ms)
- Input voltage range "1" signal 8 V DC ... 28.8 V DC
- Output name O1A, O1B, O2A, O2B
- Number of outputs 4
- Ohmic load min. 50 Ω (Observe limiting continuous current)
- Output voltage when switched off max. 0.1 V
- Test pulses ≤ 220 µs (Test pulse duration)
- Response time see user manual
- Net weight 141 g
- Protection class III (EN 50178)
- Indication 2 x LED (red)
- Stop category 0
- Overvoltage category II
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- Height 107.74 mm
- Designation Air clearances and creepage distances between the power circuits
- Input name Enable inputs
- Input current range "0" signal < 1 mA
- Nominal output voltage range 18 V DC ... 27.6 V DC (US - 1.2 V)
- Max. capacitive load max. 470 nF
- Discharging circuit Yes, internal
- Restart time min. 5 s (Boot time)
- Nominal operating mode 100% operating factor
- Housing color yellow
- Housing material Polyamide PA non-reinforced
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Safety Integrity Level (SIL) 2
- Safety Integrity Level Claim Limit (SIL CL) 3 (2-channel wiring)
- Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
- ECLASS 9.0 27371819
- Ambient temperature (storage/transport) -20 °C ... 85 °C
- Rated control supply current IS typ. 55 mA (Outputs inactive)
- Description of the input IEC 61131-2 type 3
- Protective circuit/component Suppressor diode
- Output description PNP, IEC 61131-2 type 0.5
- Switching frequency max. 1/4 x tCycle [Hz]
- Error detection time at 1-channel structure < 3.5 s (OFF state)
- Maximum inrush current 1.1 A (Δt = 3 s at Us)
- Mounting position vertical or horizontal
- Assembly instructions Observe derating
- Connection method Push-in connection
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Performance level (PL) e (2-channel wiring)
- Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- ECLASS 10.0.1 27371819
- Ambient temperature (operation) -10 °C ... 55 °C (observe derating)
- Maximum altitude ≤ 2000 m (Above sea level)
- Current consumption typ. 0.7 mA (typically with US)
- Protective circuit Inverse-parallel protection against polarity reversal
- Input voltage range "0" signal 0 V DC ... 5 V DC
- Cable length max. 100 m (per output)
- Nominal output voltage 24 V DC (Supply via A1)
- Limiting continuous current 100 mA (per channel)
- Max. inductive load max. 2.4 mH
- Voltage 24 V DC (via A1)
- Cycle time see user manual
- Degree of protection IP20
- Operating voltage display 1 x green LED
- pluggable Yes
- Stripping length 10 mm
- Standards/regulations EN 50178
- Degree of pollution 2
- ECLASS 11.0 27371819
- Nominal voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Mounting type DIN rail mounting
- Min. degree of protection of inst. location IP54
- Status display 1 x LED (green), 1 x LED (orange), 1 x LED (blue)
- Conductor cross-section AWG 24 ... 16
- Rated insulation voltage 250 V AC
- Conformance CE-compliant
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 5 days!
1-year warranty
$491.24
Stock:
12
Select Qty:
$491.24
$491.24 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.