Safe extension module with 4 safe outputs (0.4 A), 4 reset inputs, 4 signal outputs, TBUS interface, up to SILCL 3, cat. 4/PL e, SIL 3, plug-in screw terminal block, TBUS connector included
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1104856 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 112.58 mm
- Depth 113.6 mm
- Designation Air clearances and creepage distances between the power circuits
- Filter time 250 ms ±2 ms (Test pulse rate > 500 ms)
- Input name Reset inputs
- Voltage 24 V DC (via A1)
- Ambient temperature (storage/transport) -20 °C ... 85 °C
- Rated control circuit supply voltage US 24 V DC -20 % / +20 % (provide external protection, typically 5 A)
- Description Output supply, connected internally to A1/A2
- Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US)
- Output description PNP, IEC 61131-2 Typ 0,1
- Leakage current max. 100 µA
- Max. capacitive load max. 680 nF
- Switching frequency max. 1/4 x tCycle [Hz]
- Output voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Maximum inrush current 1.1 A (Δt = 3 s at Us)
- Mounting position vertical or horizontal
- Mounting type DIN rail mounting
- Housing color yellow
- Operating voltage display 1 x green LED
- Max. permissible humidity (storage/transport) 95 % (non-condensing)
- Power consumption at US typ. 0.72 W (Outputs inactive)
- Input voltage range "0" signal 0 V DC ... 5 V DC
- Input current range "0" signal < 1 mA
- Cable length max. 100 m (per output)
- Nominal output voltage 24 V DC (Supply via A1)
- Max. inductive load max. 1.4 mH
- Discharging circuit Yes, internal
- Cycle time see user manual
- Net weight 159 g
- Protection class III (EN 50178)
- Connection method Screw connection
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Stop category 0
- Rated surge voltage/insulation Basic insulation 4 kV between 24 V power supply and I/Os to the housing
- Rated insulation voltage 250 V AC
- ECLASS 10.0.1 27371819
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- Width 22.61 mm
- Max. permissible relative humidity (operation) 95 % (non-condensing)
- Rated control supply current IS See supply A1/A2
- Protective circuit Serial protection against polarity reversal
- Number of inputs 4
- Input voltage range "1" signal 11 V DC ... 28.8 V DC
- Number of outputs 4
- Ohmic load min. 50 Ω (Observe limiting continuous current)
- Error detection time at 1-channel structure < 3.5 s (OFF state)
- Nominal operating mode 100% operating factor
- Min. degree of protection of inst. location IP54
- Housing material Polyamide PA non-reinforced
- pluggable Yes
- Torque 0.5 Nm ... 0.6 Nm
- Safety Integrity Level (SIL) 2
- Safety Integrity Level Claim Limit (SIL CL) 3 (2-channel wiring)
- Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
- ECLASS 9.0 27371819
- Ambient temperature (operation) -10 °C ... 55 °C (observe derating)
- Maximum altitude ≤ 2000 m (Above sea level)
- Inrush current max. 750 mA (Δt 1 s)
- Description of the input IEC 61131-2 type 3
- Protective circuit/component Suppressor diode
- Output name O1A, O1B, O2A, O2B, O3A, O3B, O4A, O4B
- Output voltage when switched off max. 0.1 V
- Test pulses < 80 µs (Test pulse width of low test pulses)
- Response time see user manual
- Assembly instructions Observe derating
- Status display 1 x LED (green), 2 x LED (orange)
- Stripping length 7 mm
- Standards/regulations EN 50178
- Conformance CE-compliant
- Current consumption typ. 10 mA (typically with US)
- Nominal output voltage range 18 V DC ... 27.6 V DC (US - 1.2 V)
- Limiting continuous current 100 mA (per channel)
- Short-circuit protection Yes (self-limitation at 1.1 A)
- Restart time min. 5 s (Boot time)
- Degree of protection IP20
- Indication 2 x LED (red)
- Screw thread M3
- Degree of pollution 2
- ECLASS 11.0 27371819
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Conductor cross-section AWG 24 ... 12
- Performance level (PL) e (2-channel wiring)
- Overvoltage category II
- Vibration (operation) 10 Hz ... 150 Hz, 2g
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$533.46
Stock:
9
Select Qty:
$533.46
$533.46 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨