1089135 Phoenix Contact Data & Networking Devices
Part#:1089135
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Checking verified in-stock parts...
About the product: Managed Switch 2000, 6 RJ45 ports 10/100/1000 Mbps, 2 SFP ports 100/1000 Mbps, degree of protection: IP20, PROFINET Conformance-Class B, PROFINET mode preset, PROFINET status LEDs
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 1089135 Phoenix Contact price in the box on the right side or send a quick quote.
1089135 Product Details
- Interface SFP module
- Height 110 mm
- Ambient temperature (operation) -40 °C ... 70 °C
- Note on the connection method Auto negotiation and autocrossing
- Basic functions Store-and-forward switch, complies with IEEE 802.3
- Redundancy MRP (Media Redundancy Protocol)
- PROFINET device function PROFINET device
- Maximum conductor length (twisted pair) 100 m
- Mounting type DIN rail
- Housing material Stainless steel 1.4301
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG max. 16
- Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A
- Type of test Free fall in accordance with EN 61131-2
- Noise immunity EN 61000-6-2
- China RoHS Environmentally Friendly Use Period = 50 years
- Depth 69 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- No. of ports 2 (SFP ports)
- Transmission length up to 80 km (depending on the SFP module used)
- Additional functions Jumbo frames (Max. 9,600 bytes)
- Time synchronization SNTP (Simple Network Time Protocol)
- Supply voltage 24 V DC (redundant)
- Type AX Block design
- Max. current consumption 350 mA (US = min, Tamb = max)
- Note Support by phone or on-site (fee is charged)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A
- Noise emission EN 61000-6-4
- Noxious gas test ISA S71.04.2013 G3 Harsh Group A
- UL, USA UL 61010-1, Ed. 3
- Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
- Transmission speed 100/1000 Mbps (full duplex)
- Management Web-based management (HTTP/HTTPS)
- PROFINET conformance class Conformance-Class B
- Status and diagnostic indicators LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (link/activity and speed), PROFINET status LEDs (BF, SF)
- Residual ripple 3.6 VPP (within the permitted voltage range)
- Typical current consumption 260 mA (at US = 24 V DC and 25 °C ambient temperature)
- Net weight 650 g
- MTTF 357.82 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
- Conductor cross section flexible min. 0.2 mm²
- Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
- Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
- Shock (operation) 30g (EN 60068-2-27)
- Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Degree of protection IP20
- Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (operation) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
- Configuration memory max. 8 GByte (SD card)
- Diagnostic functions RMON History
- IP parameterization DHCP-Client
- Port security MAC-based, RADIUS (IEEE 802.1X)
- Cascading depth Network, linear, and star structure: any
- Material base plate Die-cast aluminum, corrosion-resistant
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section flexible max. 2.5 mm²
- Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
- Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6
- ECLASS 11.0 19170401
- Width 128 mm
- Degree of pollution 2
- Signal LEDs Data receive, link status
- Transmission physics Depending on the SFP module
- Filter functions Quality of Service (8 priority classes)
- MAC address table 8k
- Signal contact control voltage typ. 24 V DC
- Supply voltage range 19.2 V DC ... 32 V DC
- Special properties PROFINET mode preset, PROFINET status LEDs
- Connection method Push-in spring connection
- Conductor cross section AWG min. 24
- Stripping length 10 mm
- Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
- Free from substances that could impair the application of coating Yes
- UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3
- ECLASS 10.0.1 19170401
- REACh SVHC Lead 7439-92-1
- ECLASS 9.0 19170106
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨