Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1075388 Phoenix Contact Terminal Blocks

Phoenix Contact 1075388 Test disconnect terminal block, connection method: Screw connection with spring support, cross section: 0.2 mm² - 10 mm² , AWG: 24 - 10, width: 8.2 mm, mounting type: NS 35/7,5, NS 35/15, NS 32, color: gray
Phoenix Contact

Part#:1075388

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Test disconnect terminal block, connection method: Screw connection with spring support, cross section: 0.2 mm² - 10 mm² , AWG: 24 - 10, width: 8.2 mm, mounting type: NS 35/7,5, NS 35/15, NS 32, color: gray

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1075388 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • ECLASS 10.0.1
    27141126
  • Result of surge voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Bending test turns
    135
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Insulating material group
    I
  • Maximum load current
    57 A (with 10 mm² conductor cross section)
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • ECLASS 4.1
    27141126
  • Number of connections
    2
  • Rated surge voltage
    8 kV
  • Static insulating material application in cold
    -60 °C
  • Width
    8.2 mm
  • Height NS 32
    58 mm
  • Tightening torque max
    1.8 Nm
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section AWG max.
    8
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    4 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141126
  • ECLASS 9.0
    27141126
  • UNSPSC 11
    39121410
  • UNSPSC 21.0
    39121410
  • Insulating material
    PA
  • Degree of pollution
    3
  • Maximum power dissipation for nominal condition
    1.31 W
  • Open side panel
    Yes
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Power frequency withstand voltage setpoint
    2.2 kV
  • ASD level
    1.2 g2/Hz
  • Tightening torque, min
    1.5 Nm
  • Conductor cross section flexible max.
    6 mm²
  • Min. AWG conductor cross section, flexible
    24
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • 2 conductors with same cross section, solid max.
    2.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC000902
  • UNSPSC 13.2
    39121410
  • Potentials
    1
  • Overvoltage category
    III
  • Nominal current IN
    41 A
  • Finger protection
    guaranteed
  • Surge voltage test setpoint
    9.8 kV
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Conductor cross section tensile test
    1.5 mm²
  • Tight fit on carrier
    NS 32/NS 35
  • Conductor cross section short circuit testing
    6 mm²
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Stripping length
    12 mm
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • Internal cylindrical gage
    A5
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141126
  • ETIM 2.0
    EC000902
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Length
    88.5 mm
  • Connection method
    Screw connection with spring support
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • 2 conductors with same cross section, stranded max.
    2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27141126
  • ECLASS 7.0
    27141126
  • ETIM 4.0
    EC000902
  • ETIM 6.0
    EC000902
  • UNSPSC 12.01
    39121410
  • ETIM 7.0
    EC000902
  • UNSPSC 18.0
    39121410
  • Max. AWG conductor cross section, flexible
    10
  • ECLASS 6.0
    27141100
  • UNSPSC 7.0901
    39121410
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • UNSPSC 20.0
    39121410
  • Nominal voltage UN
    1000 V
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of tight fit on support
    Test passed
  • Back of the hand protection
    guaranteed
  • Bending test rotation speed
    10 rpm
  • Oscillation, broadband noise test result
    Test passed
  • Color
    gray
  • Requirements, voltage drop
    U1 ≤ 6,4 mV (1,6 mV x number of conductorclamping units or disconnect unit contactpoints)U2 ≤ 1,5 x U1
  • Short-time current
    0.72 kA
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Test duration per axis
    5 h
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Screw thread
    M4
  • Nominal cross section
    6 mm²
  • Tensile test result
    Test passed
  • Tractive force setpoint
    40 N
  • Short circuit stability result
    Test passed
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Height NS 35/7,5
    53 mm
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/15
    60.5 mm
  • Result of thermal test
    Test passed
  • Acceleration
    30g
  • Shock duration
    18 ms
  • Number of shocks per direction
    3
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock form
    Semi-sinusoidal
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Shock test result
    Test passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Connection
    1 level

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo