1067327 Phoenix Contact UPS (DC)

Phoenix Contact 1067327 QUINT UPS, IQ Technology, DIN rail mounting, USB (Modbus/RTU), input:120 V AC / 230 V AC, output:120 V AC / 230 V AC / 500 VA.
Phoenix Contact

Part#:1067327

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: QUINT UPS, IQ Technology, DIN rail mounting, USB (Modbus/RTU), input:120 V AC / 230 V AC, output:120 V AC / 230 V AC / 500 VA.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 1067327 Phoenix Contact price in the box on the right side or send a quick quote.

1067327 Product Details

  • Depth
    125 mm
  • Ambient temperature (operation)
    -25 °C ... 60 °C (> 50 °C: 2,5 % / K)
  • Typical national grid voltage
    120 V AC
  • Current consumption, battery operation
    19 A (24 V DC)
  • Switch-over time
    < 10 ms
  • Overload capability, battery operation
    105 % (Permanent)
  • Output fuse, voltage
    400 V
  • Height
    130 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 %
  • Input voltage range
    90 V AC ... 264 V AC
  • Frequency range (fN)
    45 Hz ... 65 Hz
  • Real power
    400 W
  • Connection in series
    No
  • Width
    180 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Input voltage
    24 V DC
  • Permissible backup fuse
    50 A
  • Power factor (cos phi)
    0.8
  • UPS classification
    VFD-SS-311
  • Output voltage
    120 V AC ±2 %
  • Installation distance right/left
    0 mm / 0 mm
  • Degree of protection
    IP20
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Current consumption
    6.9 A (100 V AC)
  • Crest factor
    2.8
  • Apparent power
    500 VA
  • Nominal capacity range
    3.4 Ah ... 190 Ah (5x 38 Ah)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Installation height
    ≤ 3000 m (> 2000 m: 0,6 % / 100 m)
  • Voltage type of supply voltage
    AC
  • Connection in parallel
    no
  • Overload capability, mains operation
    in accordance with internal fuse
  • Nominal output current (IN)
    4.17 A (120 V AC)
  • Output fuse, current
    10 A
  • Fuse
    gRL
  • Deep discharge protection
    20 V DC ... 24 V DC (can be parameterized)
  • Fast transients (burst)
    EN 61000-4-4
  • Output
    ± 2 kV
  • Power frequency magnetic field
    EN 61000-4-8
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Installation distance top/bottom
    50 mm / 50 mm
  • Maximum power dissipation in no-load condition
    approx. 23 W (120 V AC)
  • Power loss nominal load max.
    approx. 57 W (120 V AC)
  • Nominal output frequency
    60 Hz
  • Form of output voltage
    Pure sine
  • Total harmonic distortion factor (THD)
    < 3 % (linear load)
  • Charge current
    max. 5 A
  • Battery technology
    VRLA, VRLA-WTR, LI-ION (see section: Ordering data)
  • MTBF (IEC 61709, SN 29500)
    445469 h (40 °C)
  • Protection class
    I
  • Connection method
    Screw connection
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm²
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Torque
    0.5 Nm ... 0.6 Nm
  • Interface
    USB (Modbus/RTU)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    0.15 MHz ... 80 MHz
  • Comments
    Criterion A
  • Input
    ± 2 kV
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 9.0
    27040705
  • End-of-charge voltage
    24 V DC ... 31 V DC (temperature compensated)
  • Charge characteristic curve
    IU0U
  • Net weight
    2.5 kg
  • Efficiency
    > 97 % (100 % load, with charged energy storage)
  • Stripping length
    8 mm
  • Flexible conductor cross section (ferrule with plastic sleeve)
    0.2 mm² ... 1.5 mm²
  • Flexible conductor cross section flexible (ferrule, w/o plastic sleeve)
    0.2 mm² ... 1.5 mm²
  • Conductor cross section AWG
    30 ... 12
  • Standards/regulations
    EN 62040-1
  • Standard designation
    Uninterruptible power supply systems
  • Electrostatic discharge
    EN 61000-4-2
  • Contact discharge
    ± 6 kV
  • Discharge in air
    ± 8 kV
  • Test field strength
    10 V/m
  • Signal
    30 A/m
  • Conducted interference
    EN 61000-4-6
  • Frequency
    50 Hz

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo