1046881 Phoenix Contact DC/DC Converters
Part#:1046881
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Screw connection, input: 24 V DC , output: 24 V DC / 20 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1046881 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight1.2 kg
- Input voltage range 18 V DC ... 32 V DC
- Switch-on time < 1 s
- Inrush current limitation typical 2.7 A (after 1 ms)
- Production test C 0.5 kV DC
- Connection method Push-in connection
- Typical current consumption 27 A (24 V DC)
- Type test (IEC/EN 60950-1) A 2 kV DC
- Type test (IEC/EN 60950-1) B 4 kV DC
- Production test B 2 kV DC
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Torque 0.6 Nm ... 0.8 Nm
- Dynamic Boost (IDyn.Boost) 30 A (5 s)
- System deviation, input voltage change < 0.4 % (change in input voltage ±10 %)
- Feedback voltage resistance ≤ 35 V DC
- Types of signaling LED
- Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
- Signal option Output current
- Reference potential to OUT1, OUT2, REM
- Voltage 1 kV
- Hood version Stainless steel X6Cr17
- Height 130 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min, resonance frequency 2.3g, 90 min
- EMC requirements for noise immunity EN 61000-6-1
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Additional text Test Level 2
- Contact discharge 8 kV (Test Level 4)
- Fast transients (burst) EN 61000-4-4
- I/O/S asymmetrical
- Frequency 0 Hz
- Pulse-shape magnetic field EN 61000-4-9
- Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
- Input, output (test level 2) 1 MHz (Test Level 2 - asymmetrical)
- ECLASS 10.0.1 27210901
- Electric strength, max. 35 V DC (60 s)
- Insulation voltage input/output 4 kV DC (type test)
- Type test (IEC/EN 60950-1) D 0.5 kV DC
- Conductor cross section solid 0.2 mm² ... 1 mm²
- Conductor cross section AWG 24 ... 16
- Selective Fuse Breaking (ISFB) 120 A (15 ms)
- Short-circuit-proof yes
- Connection in series yes
- Connection labeling 3.4 +
- Function Signal ground
- Temperature 30 °C
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Efficiency typ. 94.7 % (24 V DC)
- Power dissipation SLEEP MODE < 2 W
- Degree of pollution 2
- EMC requirements, power plant IEC 61850-3
- Conducted noise emission EN 55016
- DNV GL conducted interference Class B
- Discharge in air 15 kV (Test Level 4)
- Test field strength 100 A/m
- Conducted interference EN 61000-4-6
- Voltage dips EN 61000-4-29
- Damped oscillating magnetic field EN 61000-4-10
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 9.0 27210901
- Mains buffering typ. 16 ms (24 V DC)
- Inrush current integral (I2t) < 0.2 A2s
- Production test A 2 kV DC
- Stripping length 8 mm
- Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 0.75 mm²
- Nominal output voltage (UN) 24 V DC
- Nominal output current (IN) 20 A
- System deviation, static < 3 % (change in load, static 10 % ... 90 %)
- Connection in parallel Yes, for redundancy and increased capacity
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- UIn > 0.8 x UInNom (LED off)
- Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
- Output current 20 A
- Degree of protection IP20
- Width with alternative assembly 122 mm
- Depth with alternative assembly 73 mm
- Maximum power dissipation in no-load condition < 4 W
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Identification IECEx SIQ 20.0002X
- Noise emission EN 55016
- Comments Criterion A
- Signal 2 kV (Test Level 3 - asymmetrical)
- Voltage dip 0 %
- Test level 1 15 Hz 150 Hz (Test Level 3)
- Attenuated oscillating wave EN 61000-4-18
- Alternating component of DC voltage EN 61000-4-17
- Signals (test level 2) 1 MHz (Test Level 2 - asymmetrical)
- Typical response time 300 ms (from SLEEP MODE)
- Type test (IEC/EN 60950-1) C 0.5 kV DC
- Production test D 0.5 kV DC
- Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.2 mm² ... 1.5 mm²
- Static Boost (IStat.Boost) 25 A
- System deviation, dynamic < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- No-load proof yes
- Rise time < 1 s (UOUT (10 % ... 90 %))
- UOut > 0.9 x USet (LED lights up green)
- Digital 0 V DC
- Maximum contact load 24 V DC
- Time 278680 h
- Main converter stage 67 kHz ... 135 kHz (Main converter stage)
- Width 70 mm
- Height with alternative assembly 130 mm
- Ambient temperature (operation) -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- Standard designation Railway applications
- Standards/regulations EN 50121-3-2
- DNV GL noise radiation Class B
- Electromagnetic HF field EN 61000-4-3
- Frequency range 50 Hz ... 60 Hz
- Input 1 kV (Test Level 3 - symmetrical)
- Power frequency magnetic field EN 61000-4-8
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Test level 4 15 kHz 150 kHz (Test Level 3)
- Input, output (test level 1) 1 MHz (Test Level 2 - symmetrical)
- Input, output (test level 3) 10 MHz (Test Level 2 - asymmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity)
- Magnetic circuit breaker tripping A1...A16 / B2...B13 / C1...C6 / Z1...Z16
- Residual ripple < 50 mVPP
- POut > 100 % (LED lights up yellow, output power > 480 W)
- Switch contact floating
- MTBF (IEC 61709, SN 29500) > 1034000 h (25 °C)
- Auxiliary converter stage 190 kHz ... 220 kHz (Auxiliary converter stage)
- Protection class Special with SELV input and output
- Side element version Aluminum
- Depth 125 mm
- Power loss nominal load max. < 26.6 W
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- Climatic class 3K3 (EN 60721)
- Designation IECEx
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electrostatic discharge EN 61000-4-2
- Output 1 kV (Test Level 3 - symmetrical)
- Surge voltage load (surge) EN 61000-4-5
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- Signals (test level 1) 1 MHz (Test Level 2 - symmetrical)
- ECLASS 11.0 27210901
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨