About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1046803 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight0.8 kg
- Typical current consumption 13.8 A (24 V DC)
- Inrush current limitation typical 1.5 A (after 1 ms)
- Type test (IEC/EN 60950-1) C 0.5 kV DC
- Type test (IEC/EN 60950-1) D 0.5 kV DC
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 0.75 mm²
- Dynamic Boost (IDyn.Boost) 20 A (5 s)
- Short-circuit-proof yes
- System deviation, input voltage change < 0.1 % (change in input voltage ±10 %)
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- UOut > 0.9 x USet (LED lights up green)
- Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
- Temperature 30 °C
- Protection class Special with SELV input and output
- Height with alternative assembly 130 mm
- Power loss nominal load max. < 16 W
- Electric strength, max. 35 V DC (60 s)
- Switch-on time < 1 s
- Input fuse 30 A (slow-blow, internal)
- Production test C 0.5 kV DC
- Connection method Push-in connection
- Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
- Magnetic circuit breaker tripping A1...A6 / B2...B6 / C1...C3 / Z1...Z6
- Residual ripple < 50 mVPP
- Rise time < 1 s (UOUT (10 % ... 90 %))
- Connection labeling 3.4 +
- Function Signal ground
- Time 422400 h
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Depth with alternative assembly 53 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- Standard designation Mains variation/undervoltage
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- DNV GL noise radiation Class B
- Electromagnetic HF field EN 61000-4-3
- Output 1 kV (Test Level 3 - symmetrical)
- I/O/S asymmetrical
- Pulse-shape magnetic field EN 61000-4-9
- Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
- Input, output (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- REACh SVHC Lead 7439-92-1
- ETIM 7.0 EC002046
- Input voltage range 18 V DC ... 32 V DC
- Typical response time 300 ms (from SLEEP MODE)
- Type test (IEC/EN 60950-1) B 4 kV DC
- Production test D 0.5 kV DC
- Conductor cross section AWG 24 ... 16
- Nominal output voltage (UN) 24 V DC
- Nominal output current (IN) 10 A
- System deviation, dynamic < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- Connection in series yes
- Types of signaling LED
- UIn > 0.8 x UInNom (LED off)
- Maximum contact load 24 V DC
- Reference potential to OUT1, OUT2, REM
- Degree of protection IP20
- Side element version Aluminum
- Width 50 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- EMC requirements for noise emission EN 61000-6-3
- Identification ABS
- Conducted noise emission EN 55016
- DNV GL conducted interference Class B
- Frequency range 50 Hz ... 60 Hz
- Signal 2 kV (Test Level 3 - asymmetrical)
- Voltage dip 0 %
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Alternating component of DC voltage EN 61000-4-17
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Mains buffering typ. 11 ms (24 V DC)
- Type test (IEC/EN 60950-1) A 2 kV DC
- Production test A 2 kV DC
- Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.2 mm² ... 1.5 mm²
- Static Boost (IStat.Boost) 12.5 A
- No-load proof yes
- Feedback voltage resistance ≤ 35 V DC
- Digital 0 V DC
- Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
- Switch contact floating
- Output current 10 A
- Main converter stage 67 kHz ... 135 kHz (Main converter stage)
- Hood version Stainless steel X6Cr17
- Depth 125 mm
- Width with alternative assembly 122 mm
- Maximum power dissipation in no-load condition < 5 W
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Climatic class 3K3 (EN 60721)
- EMC requirements for noise immunity EN 61000-6-1
- Designation Shipbuilding
- Additional text Test Level 2
- Contact discharge 8 kV (Test Level 4)
- Input 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- Voltage dips EN 61000-4-29
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Input, output (test level 3) 10 MHz (Test Level 2 - asymmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27210901
- ETIM 6.0 EC002046
- Inrush current integral (I2t) < 0.02 A2s
- Insulation voltage input/output 4 kV DC (type test)
- Production test B 2 kV DC
- Stripping length 8 mm
- Conductor cross section solid 0.2 mm² ... 1 mm²
- Selective Fuse Breaking (ISFB) 60 A (15 ms)
- System deviation, static < 1 % (change in load, static 10 % ... 90 %)
- Connection in parallel Yes, for redundancy and increased capacity
- POut > 100 % (LED lights up yellow, output power > 240 W)
- Signal option Output current
- MTBF (IEC 61709, SN 29500) > 1380000 h (25 °C)
- Voltage 1 kV
- Auxiliary converter stage 190 kHz ... 220 kHz (Auxiliary converter stage)
- Height 130 mm
- Efficiency typ. 93.3 % (24 V DC)
- Power dissipation SLEEP MODE < 2 W
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
- Overvoltage category EN 62477-1 III
- EMC requirements, power plant IEC 61850-3
- Noise emission EN 55016
- Discharge in air 15 kV (Test Level 4)
- Test field strength 100 A/m
- Fast transients (burst) EN 61000-4-4
- Frequency 0 Hz
- Damped oscillating magnetic field EN 61000-4-10
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Attenuated oscillating wave EN 61000-4-18
- Signals (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- ECLASS 11.0 27210901
- Ambient temperature (start-up type tested) -40 °C
- Overvoltage category EN 61010-1 II
- Standards/regulations EN 61000-4-29
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electrostatic discharge EN 61000-4-2
- Comments Criterion A
- Surge voltage load (surge) EN 61000-4-5
- Power frequency magnetic field EN 61000-4-8
- Test level 1 15 Hz 150 Hz (Test Level 3)
- Test level 4 15 kHz 150 kHz (Test Level 3)
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 9.0 27210901
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨