1046803 Phoenix Contact DC/DC Converters

Phoenix Contact 1046803 Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, screw connection, input: 24 V DC, output: 24 V DC / 10 A
Phoenix Contact

Part#:1046803

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, screw connection, input: 24 V DC, output: 24 V DC / 10 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1046803 Phoenix Contact price in the box on the right side or send a quick quote.

1046803 Product Details

  • Typical current consumption
    13.8 A (24 V DC)
  • Inrush current limitation typical
    1.5 A (after 1 ms)
  • Type test (IEC/EN 60950-1) C
    0.5 kV DC
  • Type test (IEC/EN 60950-1) D
    0.5 kV DC
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Flexible conductor cross section (ferrule with plastic sleeve)
    0.2 mm² ... 0.75 mm²
  • Dynamic Boost (IDyn.Boost)
    20 A (5 s)
  • Short-circuit-proof
    yes
  • System deviation, input voltage change
    < 0.1 % (change in input voltage ±10 %)
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • UOut
    > 0.9 x USet (LED lights up green)
  • Analog
    4 mA ... 20 mA ±5 % (Load ≤400 Ω)
  • Temperature
    30 °C
  • Protection class
    Special with SELV input and output
  • Height with alternative assembly
    130 mm
  • Power loss nominal load max.
    < 16 W
  • Electric strength, max.
    35 V DC (60 s)
  • Switch-on time
    < 1 s
  • Input fuse
    30 A (slow-blow, internal)
  • Production test C
    0.5 kV DC
  • Connection method
    Push-in connection
  • Setting range of the output voltage (USet)
    24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
  • Magnetic circuit breaker tripping
    A1...A6 / B2...B6 / C1...C3 / Z1...Z6
  • Residual ripple
    < 50 mVPP
  • Rise time
    < 1 s (UOUT (10 % ... 90 %))
  • Connection labeling
    3.4 +
  • Function
    Signal ground
  • Time
    422400 h
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Depth with alternative assembly
    53 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • Standard designation
    Mains variation/undervoltage
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • DNV GL noise radiation
    Class B
  • Electromagnetic HF field
    EN 61000-4-3
  • Output
    1 kV (Test Level 3 - symmetrical)
  • I/O/S
    asymmetrical
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 6
    0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
  • Input, output (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • REACh SVHC
    Lead 7439-92-1
  • ETIM 7.0
    EC002046
  • Input voltage range
    18 V DC ... 32 V DC
  • Typical response time
    300 ms (from SLEEP MODE)
  • Type test (IEC/EN 60950-1) B
    4 kV DC
  • Production test D
    0.5 kV DC
  • Conductor cross section AWG
    24 ... 16
  • Nominal output voltage (UN)
    24 V DC
  • Nominal output current (IN)
    10 A
  • System deviation, dynamic
    < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
  • Connection in series
    yes
  • Types of signaling
    LED
  • UIn
    > 0.8 x UInNom (LED off)
  • Maximum contact load
    24 V DC
  • Reference potential
    to OUT1, OUT2, REM
  • Degree of protection
    IP20
  • Side element version
    Aluminum
  • Width
    50 mm
  • Weight
    0.8 kg
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • EMC requirements for noise emission
    EN 61000-6-3
  • Identification
    ABS
  • Conducted noise emission
    EN 55016
  • DNV GL conducted interference
    Class B
  • Frequency range
    50 Hz ... 60 Hz
  • Signal
    2 kV (Test Level 3 - asymmetrical)
  • Voltage dip
    0 %
  • Test level 2
    150 Hz 1.5 kHz (Test Level 3)
  • Alternating component of DC voltage
    EN 61000-4-17
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Mains buffering
    typ. 11 ms (24 V DC)
  • Type test (IEC/EN 60950-1) A
    2 kV DC
  • Production test A
    2 kV DC
  • Flexible conductor cross section flexible (ferrule, w/o plastic sleeve)
    0.2 mm² ... 1.5 mm²
  • Static Boost (IStat.Boost)
    12.5 A
  • No-load proof
    yes
  • Feedback voltage resistance
    ≤ 35 V DC
  • Digital
    0 V DC
  • Default
    Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
  • Switch contact
    floating
  • Output current
    10 A
  • Main converter stage
    67 kHz ... 135 kHz (Main converter stage)
  • Hood version
    Stainless steel X6Cr17
  • Depth
    125 mm
  • Width with alternative assembly
    122 mm
  • Maximum power dissipation in no-load condition
    < 5 W
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Climatic class
    3K3 (EN 60721)
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Designation
    Shipbuilding
  • Additional text
    Test Level 2
  • Contact discharge
    8 kV (Test Level 4)
  • Input
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Voltage dips
    EN 61000-4-29
  • Test level 3
    1.5 kHz 15 kHz (Test Level 3)
  • Input, output (test level 3)
    10 MHz (Test Level 2 - asymmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27210901
  • ETIM 6.0
    EC002046
  • Inrush current integral (I2t)
    < 0.02 A2s
  • Insulation voltage input/output
    4 kV DC (type test)
  • Production test B
    2 kV DC
  • Stripping length
    8 mm
  • Conductor cross section solid
    0.2 mm² ... 1 mm²
  • Selective Fuse Breaking (ISFB)
    60 A (15 ms)
  • System deviation, static
    < 1 % (change in load, static 10 % ... 90 %)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • POut
    > 100 % (LED lights up yellow, output power > 240 W)
  • Signal option
    Output current
  • MTBF (IEC 61709, SN 29500)
    > 1380000 h (25 °C)
  • Voltage
    1 kV
  • Auxiliary converter stage
    190 kHz ... 220 kHz (Auxiliary converter stage)
  • Height
    130 mm
  • Efficiency
    typ. 93.3 % (24 V DC)
  • Power dissipation SLEEP MODE
    < 2 W
  • Maximum altitude
    ≤ 5000 m (> 2000 m, observe derating)
  • Vibration (operation)
    5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
  • Overvoltage category EN 62477-1
    III
  • EMC requirements, power plant
    IEC 61850-3
  • Noise emission
    EN 55016
  • Discharge in air
    15 kV (Test Level 4)
  • Test field strength
    100 A/m
  • Fast transients (burst)
    EN 61000-4-4
  • Frequency
    0 Hz
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Attenuated oscillating wave
    EN 61000-4-18
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • ECLASS 11.0
    27210901
  • Ambient temperature (start-up type tested)
    -40 °C
  • Overvoltage category EN 61010-1
    II
  • Standards/regulations
    EN 61000-4-29
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Electrostatic discharge
    EN 61000-4-2
  • Comments
    Criterion A
  • Surge voltage load (surge)
    EN 61000-4-5
  • Power frequency magnetic field
    EN 61000-4-8
  • Test level 1
    15 Hz 150 Hz (Test Level 3)
  • Test level 4
    15 kHz 150 kHz (Test Level 3)
  • Test level 5
    16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 9.0
    27210901

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

1046803

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo