1033485 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 1033485 Set consisting of one 1 A measuring transducer and one UV-resistant Rogowski coil with signal line. Length of Rogowski coil: 600 mm, diameter: 190 mm. Length of signal line: 3 m. The Rogowski coil measures the AC current of busbars and power lines.
Phoenix Contact

Part#:1033485

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Set consisting of one 1 A measuring transducer and one UV-resistant Rogowski coil with signal line. Length of Rogowski coil: 600 mm, diameter: 190 mm. Length of signal line: 3 m. The Rogowski coil measures the AC current of busbars and power lines.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1033485 Phoenix Contact price in the box on the right side or send a quick quote.

1033485 Product Details

  • Height
    85 mm
  • Maximum altitude
    < 2000 m
  • Nominal supply voltage range
    19.2 V DC ... 30 V DC
  • Position error
    < 1 %
  • Phase angle
    < 1 °
  • Output voltage (sinusoidal, in no-load operation)
    100 mV (VOUT = 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))
  • Diameter of measuring coil
    8.3 mm ±0.2 mm
  • Insulation
    double insulation
  • Test voltage
    1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
  • Frequency range
    45 Hz ... 65 Hz
  • Measuring coil degree of protection
    IP67 (not assessed by UL)
  • Power consumption
    4 W
  • Configurable/programmable
    Via DIP switches
  • Input signal (at 50 Hz)
    100 mV (1000 A)
  • Current output signal
    0 A AC ... 1 A
  • Typical measuring error
    < 1 %
  • Stripping length
    7 mm
  • Ambient temperature (operation)
    -30 °C ... 80 °C (Measuring coil)
  • Nominal supply voltage
    24 V DC -20 % ... +25 %
  • Frequency measuring range
    40 Hz ... 20000 Hz
  • Current consumption
    < 190 mA (at 19.2 V)
  • Connection method
    Screw connection
  • Conductor cross section AWG
    24 ... 14
  • Overvoltage category
    III (1000 V, to neutral conductor)
  • ECLASS 4.1
    27210900
  • ECLASS 7.0
    27210902
  • ETIM 7.0
    EC002048
  • Width
    22.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C (Measuring coil)
  • Measuring transducer degree of protection
    IP20
  • Connection name
    Measuring transducer side
  • Torque
    0.5 Nm ... 0.6 Nm
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • ECLASS 11.0
    27210902
  • ECLASS 10.0.1
    27210902
  • ECLASS 9.0
    27210902
  • Depth
    70.4 mm
  • Standards/regulations
    IEC 61010-1
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27210900
  • ECLASS 5.1
    27210900
  • Rated insulation voltage
    1000 V AC (rms CAT III)
  • Temperature coefficients
    0.005 %/K (+10 °C ... +70 °C, both components have the same ambient temperature)
  • Screw thread
    M3
  • Measuring ranges (current)
    100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
  • Linearity error
    < 0.5 % (From the range end value)
  • Max. distances for copper cables at PN max
    32 m (0.75 mm² (AWG 20))
  • Input impedance
    27 kΩ (smallest measuring range)
  • Load
    0 Ω ... 1.5 Ω
  • Coil material
    Elastollan
  • Maximum transmission error
    ≤ 0.5 % (From the range end value)
  • Operating voltage display
    Green LED
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27210900
  • ETIM 6.0
    EC002048
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Rated power
    1.5 VA
  • Output signal (at 50 Hz)
    100 mV (no load, at 1,000 A)
  • Length of measuring coil
    600 mm
  • Length of signal cable
    3000 mm
  • Basic accuracy
    <± 0.21 %
  • UL, USA/Canada
    UL 508 Listed
  • Pollution degree
    2
  • ECLASS 5.0
    27210900
  • Max. current consumption
    190 mA
  • Output voltage (in no-load operation)
    VOUT = M * dI/dt
  • Conductor structure signal line
    2x 0.22 mm (Signal (tinned))
  • Housing material
    Polyamide
  • Max. detectable harmonics
    < 2 kHz

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

1033485

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo