1017062 Phoenix Contact Electrical Safety Devices

Phoenix Contact 1017062 Coupling relay for electrical isolation and power adaptation for SIL 3 F&G applications, low demand, load diagnostics in the Off and On state for wire break and short circuit, 1 enabling current path, test pulse filter, plug-in screw terminal block, width
Phoenix Contact

Part#:1017062

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Coupling relay for electrical isolation and power adaptation for SIL 3 F&G applications, low demand, load diagnostics in the Off and On state for wire break and short circuit, 1 enabling current path, test pulse filter, plug-in screw terminal block, width

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1017062 Phoenix Contact price in the box on the right side or send a quick quote.

1017062 Product Details

  • Height
    112.2 mm
  • Max. permissible relative humidity (operation)
    75 % (on average, 85% infrequently, non-condensing)
  • Rated control circuit supply voltage US
    24 V DC -15 % / +10 %
  • Power consumption at US
    typ. 2 W (at US/UD; On state)
  • Inrush current at UD
    1.5 A (Δt < 10 µs)
  • Power consumption at UD
    typ. 0.9 W (at UD; Off state)
  • Protective circuit/component
    36 V suppressor diode
  • Output name
    Signaling current path
  • Contact material
    AgNi, gold-flashed, Ag alloy
  • Mechanical service life
    approx. 5x 107 cycles
  • Recovery time
    1 s (when controlled via A1-A2)
  • Relay type
    Electromechanical relay
  • Assembly instructions
    See derating curve
  • Housing color
    yellow
  • pluggable
    Yes
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Standards/regulations
    DIN EN 50178
  • Rated surge voltage/insulation
    Basic insulation 4 kV between all current paths and housing
  • ECLASS 10.0.1
    27371819
  • ECLASS 6.0
    27371819
  • Width
    17.5 mm
  • Ambient temperature (operation)
    -25 °C ... 60 °C (observe derating)
  • Air pressure (storage/transport)
    79 kPa ... 106 kPa
  • Rated control supply current IS
    typ. 75 mA
  • Filter time
    2 ms (at A1-A2 in the event of voltage dips at Us)
  • Protective circuit
    Surge protection 36 V suppressor diode (A1-A2)33 V suppressor diode (24V-GND)
  • Current consumption
    typ. 20 mA (Input TP1)
  • Contact type
    1 signaling current path
  • Switching capacity
    min. 1 W
  • Short-circuit protection
    no
  • Typical release time at US
    typ. 30 ms (when controlled via A1-A2)
  • Mounting position
    vertical or horizontal
  • Mounting type
    DIN rail mounting
  • Status display
    1 x yellow LED, 1 x green LED, 1 x red LED
  • Connection method
    Screw connection
  • Rated insulation voltage
    250 V AC
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g
  • Conformance
    CE-compliant
  • ECLASS 5.1
    27371901
  • ETIM 7.0
    EC001449
  • Ambient temperature (storage/transport)
    -40 °C ... 65 °C
  • Conductor cross-section AWG
    24 ... 12
  • Shock
    15g, 11 ms
  • ECLASS 11.0
    27371819
  • ECLASS 9.0
    27371819
  • Utilization restriction
    Use in potentially explosive areas is not permitted in China.
  • Air pressure (operation)
    79 kPa ... 106 kPa
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Diagnostic supply voltage UD
    24 V DC -20 % / +25 %
  • Description of the input
    Test point for proof test
  • Type of protection
    Surge protection
  • Number of outputs
    1 (without delay, floating)
  • Limiting continuous current
    3 A (Observe derating, load type, and on-load voltage)
  • Sq. Total current
    9 A2 (observe derating)
  • Typical pickup time at US
    typ. 100 ms (when controlled via A1-A2)
  • Nominal operating mode
    100% operating factor
  • Min. degree of protection of inst. location
    IP54
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Screw thread
    M3
  • Safety Integrity Level (SIL)
    3 (Reference IEC 61508)
  • Overvoltage category
    III
  • REACh SVHC
    Lead 7439-92-1
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Depth
    114.5 mm
  • Max. permissible humidity (storage/transport)
    75 % (on average, 85% infrequently, non-condensing)
  • Inrush current
    max. 800 mA (Δt  100 ms)
  • Input current at UD
    35 mA (at UD = 24 V)
  • Number of inputs
    3
  • Output description
    non-safety-related N/C contact
  • Switching voltage
    min. 16 V AC/DC
  • Switching frequency
    max. 0.5 Hz
  • Diagnostic threshold
    7 Ω ... 20 kΩ (configurable)
  • Net weight
    221.1 g
  • Degree of protection
    IP20
  • Housing material
    Frianyl A 63 R V0
  • Stripping length
    7 mm
  • Designation
    Air clearances and creepage distances between the power circuits
  • Degree of pollution
    2
  • Environmental simulation test
    ISA-S71.04 (G3)
  • ETIM 6.0
    EC001449

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

1017062

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo