Safety relay for emergency stop, safety doors, light grid up to SILCL 3, Cat. 4, PL e, 1- or 2-channel operation, cross-circuit detection, can be retriggered, fall back/tightening delay 0.2 s to 300 s, 5 enabling current paths, US = 24 V DC, plug-in screw
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1015533 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 112.2 mm
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Designation Air clearances and creepage distances between the power circuits
- Input name Start circuit
- ETIM 7.0 EC001449
- Depth 114.5 mm
- Inrush current min. 3 mA
- Power consumption at US typ. 1.92 W
- Input current range "0" signal 0 mA ... 2 mA
- Limit frequency min. 0 Hz
- Output description PNP
- Switching voltage min. 12 V AC/DC
- Contact material AgSnO2
- Switching capacity min. 60 mW
- Output fuse 6 A gL/gG
- Short-circuit protection Yes
- Nominal operating mode 100% operating factor
- Mounting position vertical or horizontal
- Min. degree of protection of inst. location IP54
- Assembly instructions See derating curve
- pluggable Yes
- Connection method Screw connection
- Screw thread M3
- Safety Integrity Level (SIL) 3
- Standards/regulations DIN EN 50178
- Rated insulation voltage 250 V AC
- Overvoltage category III
- ECLASS 9.0 27371819
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Rated control supply current IS typ. 80 mA
- Description of the input non-safety-related
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Protective circuit/component Suppressor diode
- Contact type 5 enabling current paths
- Sq. Total current 108 A2 (observe derating)
- Switching capacity according to IEC 60947-5-1 4 A (24 V (DC13))
- Current max. 100 mA
- Typical response time at US < 40 ms (automatic start)
- Restart time < 1 s (Boot time)
- Recovery time 500 ms (following demand of the safety function)
- Mounting type DIN rail mounting
- Housing material PBT
- Status display 5 x bi-color LED
- Stripping length 7 mm
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Torque 0.5 Nm ... 0.6 Nm
- Performance level (PL) e (4 A DC13; 5 A AC15; 8760 switching cycles/year)
- Degree of pollution 2
- ECLASS 10.0.1 27371819
- ECLASS 11.0 27371819
- Width 22.5 mm
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Rated control circuit supply voltage US 24 V DC -20 % / +25 %
- Protective circuit Serial protection against polarity reversal Suppressor diode
- Input voltage range "0" signal 0 V DC ... 5 V DC
- Max. permissible overall conductor resistance 150 Ω
- Number of outputs 2
- Switching frequency 0.5 Hz (depending on the set delay time)
- Voltage corresponds to US
- Cable length max. 150 m
- Delay time range 0.2 s ... 300 s ±5 % (can be set for 47/48/58)
- Typical release time at US < 25 ms (when controlled via S12 and S22 (only for undelayed contacts))
- Category 4
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- China RoHS Environmentally Friendly Use Period = 50 years
- ETIM 6.0 EC001449
- Ambient temperature (operation) -35 °C ... 60 °C (observe derating)
- Maximum altitude ≤ 2000 m (Above sea level)
- Filter time max. 3 ms (Test pulse width of low test pulses)
- Number of inputs 1
- Current consumption < 3.2 mA (typically with US)
- Concurrence ∞
- Output name Enabling current paths
- Limiting continuous current 6 A
- Mechanical service life 10x 106 cycles
- Maximum inrush current 500 mA (Δt = 10 ms at Us)
- Typical pickup time at US 500 ms (with Us when controlled via A1)
- Net weight 155.43 g
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Degree of protection IP20
- Housing color yellow
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Conductor cross-section AWG 24 ... 12
- Stop category 0
- Safety Integrity Level Claim Limit (SIL CL) 3
- Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
- Shock 10g (operation), 15g (transport)
- Conformance CE-compliant
- REACh SVHC Lead 7439-92-1
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨